Figure 11, Inserting the dc power supply: 8010co chassis, Figure 12 – Nortel Networks 8000 Series User Manual

Page 37

Advertising
background image

Adding and replacing DC power supplies

37

Installing a DC Power Supply in an Ethernet Routing Switch 8000 Series Chassis

6

Push the new power supply partway into the bay, leaving the terminal block at
the side of the power supply exposed (

Figure 11

and

Figure 12

).

Figure 11 Inserting the DC power supply: 8010co chassis

Figure 12 Inserting the DC power supply: 8006 and 8010 chassis

7

Using a Phillips screwdriver, remove the screw that secures the plastic safety
cover to the power supply, and then remove the cover (

Figure 13 on page 38

).

Set the cover aside; you will replace it later.

Note: If you are installing the 8004DC power supply in a 8010co
Chassis and you have the optional breaker interface panel (BIP), go to
Installing the Breaker Interface Panel for the Ethernet Routing Switch
8010co Chassis
.

10340FA

+DC

-DC

9412FA