Ibsic – National Instruments GPIB-PC User Manual

Page 148

Advertising
background image

Section Four A

BASICA/QuickBASIC GPIB-PC Function Calls

©National Instruments Corp.

4A-73

GPIB-PC User Manual

BASICA/QuickBASIC

BASICA/QuickBASIC

IBSIC

IBSIC

Purpose:

Send interface clear for 100 microseconds

Format:

CALL IBSIC (BD%)

Remarks:

BD%

specifies an interface board.

The

IBSIC

function causes the GPIB-PC to assert the IFC

signal for at least 100 microseconds, provided the GPIB-PC
has System Controller capability. This action initializes
the GPIB and makes the interface board CIC and Active
Controller with ATN asserted, and is generally used when a
bus fault condition is suspected.

The IFC signal resets only the GPIB interface functions of
bus devices and not the internal device functions. Device
functions are reset with the Device Clear (DCL) and
Selected Device Clear (SDC) commands. To determine
the effect of these messages, consult the device
documentation.

The ESAC error occurs if the GPIB-PC does not have
System Controller capability.

Refer also to

IBRSC

.

Board Example:

1.

Initialize the GPIB and become CIC and Active Controller at
the beginning of a program.

100 CALL IBSIC (BRD0%)

Advertising