Common Errors and Their Solutions

Appendix B

GPIB-PC User Manual

B-6

©National Instruments Corp.

EBUS(14)

Error Condition: Command error during device call.

Solutions:

•

Find out which device is abnormally slow to accept commands
and fix the problem with the device.

•

If more time is needed to send commands, lengthen the time
limit of the board in

IBCONF

or with

IBTMO

.

ESTB(15)

Error Condition: Serial poll status byte(s) lost.

Solutions:

•

Call

IBRSP

more often to read the status bytes.

•

Ignore ESTB.

ESRQ(16)

Error Condition: SRQ stuck in the ON position.

Solutions:

•

Ignore ESRQ until all devices are found. It occurred because
the device asserting SRQ was not opened with

IBFIND

. The

automatic serial polling polls only the opened devices.

•

Check that you have used

IBFIND

to open all devices on the

GPIB that could assert SRQ. Remove any device from the bus
if it is not being accessed.

•

Using

IBIC

, attach one device at a time and determine that it

is unasserting SRQ after being polled.

•

Inspect the interconnecting cable to see that the devices are
attached and that the connectors are seated properly.