More about ibconf – National Instruments GPIB-PC User Manual

Page 31

Advertising
background image

Installation and Configuration

Section Two

GPIB-PC User Manual

2-6

©National Instruments Corp.

If errors occur, check the following:

Did you read Getting Started with your GPIB-PC and make any
required changes? If not, do so now.

Did you change hardware switch settings on your GPIB-PC
board? If so, run

IBCONF

and accurately input the new settings

for the board.

Are the

GPIB.COM

and

CONFIG.SYS

files installed in the root

directory of your boot drive? If not, check and repeat the
installation instructions.

Did you reboot your system before you ran

IBTEST

? If not, do

so now.

If you have performed these steps and

IBTEST

still fails, carefully note

all error information and call National Instruments.

If no errors occur, proceed to the end of this section to learn how to use
the software and to develop your application program.

More About

IBCONF

IBCONF

is a screen-oriented, interactive program that is included on the

distribution diskette of the GPIB-PC package.

You use

IBCONF

to edit the description in the handler of characteristics

of the devices and boards in the system. Running

IBCONF

to place this

information directly in the handler eliminates the need to restate it
inside each application program.

IBCONF

passes two groups of features to the handler. The first group

consists of the characteristics of the instruments or devices attached to
your GPIB-PC. The second group consists of the characteristics of each
GPIB-PC installed in the computer.

Advertising