Figure 6. Ring Lug Attached to the Ground Screw

Note

Additionally, attach a wire with a ring lug to all other C Series I/O module cable

shields. You must connect this wire to the ground terminal of the device using the ground
screw. The ground terminal of the device should not be attached to the common terminal
on the C Series I/O module.

Connecting Power to the NI WLS/ENET-9000 Series Device

Power on the NI WLS/ENET-9000 Series device using the included power
adapter or other 9–30 VDC power source.

10/100BaseT(X) Ethernet Port Connection

Use the RJ45 port located on the NI WLS/ENET-9000 Series device
interface to connect the device to an Ethernet network. Use a standard
Category 5 (CAT-5) Ethernet cable (a shielded cable is recommended) to
connect the NI WLS/ENET-9000 Series device to an Ethernet hub, or use
an Ethernet crossover cable to connect the NI WLS/ENET-9000 Series
device directly to a computer.

Note

Plug the standard Category 5 Ethernet cable into the RJ-45 Ethernet port on the

NI WLS-9000 Series device to configure the wireless network settings. After initial
configuration, you can remove the Ethernet cable from the NI WLS-9000 Series device
and use the device wireless capabilities.

1

Ring Lug Attached to the Ground Screw

1

RE

SE

T

LINK

/AC

T

GN

D

GN

D

PR

0

PR

1

10/1

00

INP

UT

9-3

0 V

4.5 W

MA

X

V

C

NI W

LS-9163

802.11g

C Ser

ies

Car

rie

r

WL

S LIN

K

ER

RO

R

STA

TU

S

PW

R

Advertising