NI WLS/ENET-9163 Carrier User Guide and Specifications

14

ni.com

Device Interface

Figure 7 shows the NI WLS/ENET-9163 carrier interface.

Figure 7. NI WLS/ENET-9163 Carrier Interface

Reset Button

The NI WLS/ENET-9000 Series devices are equipped with a reset button
as shown in Figure 7.

Pressing the reset button results in the following device responses:

When pressed for less than 5 seconds, the device reboots with the
current configuration.

When pressed for 5 seconds or longer, the STATUS LED turns on.
When released, the device reboots into Factory Default Mode, which
returns the device user configuration to the factory-set defaults.

1

RJ-45 Ethernet Port

2

LEDs: WLS LINK*, ACTIVE,
STATUS, and POWER

3

Reset Button

4

Trigger Connector

5

10/100 LED

6

LINK/ACT LED

7

Power Connector

* NI WLS-9163 Carrier Only.

NI WLS-9163

802.11g C Series Carrier

INPUT 9-30 V

4.5 W MAX

10/100

LINK/ACT

V

C

PFI0

PFI1

GND

RESET

GND

WLS LINK
ACTIVE
STATUS
POWER

1

4

7

3

2

6

5