Specifications, Output characteristics – National Instruments NI 9472 User Manual

Page 17

Advertising
background image

© National Instruments Corp.

17

NI 9472/9474

Typically, when a system is in sleep mode, you cannot
communicate with the modules. In sleep mode, the system
consumes minimal power and may dissipate less heat than it does
in normal mode. Refer to the Specifications section for more
information about power consumption and thermal dissipation.

Specifications

The following specifications are typical for the range –40 to 70 °C
unless otherwise noted. All voltages are relative to COM unless
otherwise noted. The specifications are the same for the NI 9472
and the NI 9474 unless otherwise noted.

Output Characteristics

Number of channels.......................... 8 digital output channels

Output type ....................................... Sourcing

Power-on output state ....................... Channels off

External power supply voltage range (V

sup

)

NI 9472....................................... 6–30 VDC
NI 9474....................................... 5–30 VDC

Advertising
This manual is related to the following products: