Safety, Ni 9472/9474 with screw terminal safety voltages – National Instruments NI 9472 User Manual

Page 21

Advertising
background image

© National Instruments Corp.

21

NI 9472/9474

Ferrules ............................................. 0.25 mm

2

to 2.5 mm

2

Weight

NI 9472/9474 with
screw terminal ............................ 150 g (5.3 oz)
NI 9472 with DSUB ................... 145 g (5.1 oz)

Safety

NI 9472/9474 with Screw Terminal Safety Voltages

Connect only voltages that are within the following limits.

Channel-to-COM .............................. 30 VDC max

Isolation

Channel-to-channel .................... None
Channel-to-earth ground

Continuous ........................... 250 V

rms

,

Measurement Category II

Withstand ............................. 2,300 V

rms

, verified by a 5 s

dielectric withstand test

Measurement Category II is for measurements performed on
circuits directly connected to the electrical distribution system.