Select the card slots – Nortel Networks 553-3901-200 User Manual

Page 15

Advertising
background image

Install ISDN BRI hardware

Page 15 of 46

ISDN Basic Rate Interface

Installation

Select the card slots

To install ISDN BRI cards, perform the following steps:

1

Identify all the slots that can contain them. First identify the modules
with unused network and peripheral card slots and then remove the
covers from the identified modules. To identify the modules, use the
following Print Programs. Table 1 lists the modules that can house
ISDN BRI cards.

LD 22 to print the system configuration and identify unused
network card slots to install MISPs

LD 20 to list unused IPE card slots to install SILCs, UILCs and
BRSCs

Table 1
ISDN BRI card location

2

Locate the card slots in the Meridian 1 modules which can house ISDN
BRI cards. Group all SILCs, UILCs, BRSCs, superloops and the MISP
that supports them in the same network group to avoid using junctors
for dedicated connections.

The following rules apply when selecting the card slots:

Modules

Supported
Systems

SILCs,
UILCs,
BRSCs

MISPs

NT5D21
Core/Network Module

51C, 61C,
81C

Network
slots
0-7

NT8D35
Network Module

81C

Network
slots
5-12

NT8D37
IPE Module

All systems

IPE slots
0-15

Advertising