Install ISDN BRI hardware

553-3901-200

Standard 7.00

January 2002

Connect Meridian 1 modules to the MDF

Meridian 1 modules connect to the MDF using NE-A25B cables with 50-pin
D-type male connectors on each end. One end of the cable plugs into the I/O
panel at the rear of the Meridian 1 module and the other end plugs into the
MDF.

Figure 6 shows the cable connection between the Meridian 1 and the MDF.

1

Determine the number of NE-A25B cables needed to connect one
module to the MDF.

2

Label each end of the cable specifying the module number, the
connector name (A, B, C), and the card type (SILC or UILC).

3

Plug one end of a cable into the appropriate connector on the I/O panel
at the rear of the Meridian 1 module. Plug the other end of the cable
into the corresponding connector on the MDF.

4

Properly identify cables on the MDF. For example, plug the cable into
connector A on the I/O panel and into the connector labeled A on the
MDF if an SILC or UILC is installed in slot 0 of an IPE module.

5

Repeat steps 2 through 4 for all cables in that module.

6

Repeat steps 1 through 5 for all modules containing SILCs and/or
UILCs.

7

Lay all the cables neatly and fasten them with cable ties.

8

Label the MDF, as necessary, using Table 2 through Table 5.

—————————— End of Procedure ——————————