Rear exit / horizontal termination – Napoleon Fireplaces Castlemore GDS26N User Manual

Page 12

Advertising
background image

12

W415-0607 / A / 01.18.08

V

1

V

2

90°

45°

90°

90°

Simple venting confi guration (only two 90° elbows)

Example 5:

V

1

= 4 ft

V

2

= 1.5 ft

V

T

=

V

1

+

V

2

= 4 + 1.5 = 5.5 ft

H

1

=

2

ft

H

2

=

1

ft

H

3

=

1

ft

H

4

=

1.5

ft

H

R

=

H

1

+

H

2

+

H

3

+

H

4

= 2 + 1 + 1 + 1.5 = 5.5 ft

H

O

= .03(four 90° elbows + one 45° elbow - 90°)

= .03(90 + 90 + 90 + 90 + 45 - 90) = 9.45 ft

H

T

=

H

R

+

H

O

= 5.5 + 9.45 = 14.95 ft

H

T

+ V

T

= 14.95 + 5.5 = 20.45 ft

Formula 1:

H

T

< 3.5V

T

3.5

V

T

= 3.5 x 5.5 = 19.25 ft

14.95 < 19.25

Formula 2:

H

T

+ V

T

< 24.75 feet

20.45 < 24.75

Since both formulas are met, this vent confi guration is
acceptable.

FIGURE 15

For vent confi gurations requiring more than two 90° elbows
the following formulas apply:

Formula 1: H

T

< 3.5V

T

Formula 2: H

T

+ V

T

< 24.75 feet

HORIZONTAL VENT RUN PLUS OFFSETS IN FEET

H

T

See graph to determine the required vertical rise

V

T

for the

required horizontal run

H

T

FIGURE 14

The shaded area within the lines represents acceptable
values for H

T

and V

T

.

REAR EXIT / HORIZONTAL TERMINATION

H

3

H

4

90°

REQUIRED

VERTICAL

RISE IN

INCHES

V

T

0

10

5

15

25

100

50

150

3.5

19.25

12.5

12

63

147

1

H

1

H

2

(H

T

) > (V

T

)