Minimum clearances to combustibles, Minimum mantel, shelf or ceiling clearances, Back wall side w a ll back wall side w a ll – Napoleon Fireplaces Castlemore GDS26N User Manual

Page 20: Rear exit top exit

Advertising
background image

20

W415-0607 / A / 01.18.08

FIGURE 34

MINIMUM MANTEL, SHELF OR CEILING CLEARANCES

1”

2”

47

1

/

2

35

1

/

2

5”

BRICK

COMBUSTIBLE

NON-COMBUSTIBLE

29

1

/

8

” MINIMUM

PLUS RISE *

0” IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.

12”

MANTEL, SHELF,

OR CEILING

REAR EXIT

TOP EXIT

* HORIZONTAL VENT SECTIONS: A minimum clearance of 1"
at the bottom and sides and 2" at the top of the vent pipe in all
horizontal runs to combustibles is required. Use fi restop spacer
W010-1313 and shield W585-0240 (supplied).

* VERTICAL VENT SECTIONS: A minimum of 1" all around the
vent pipe on all vertical runs to combustibles is required

.

Use

fi restop spacer W010-1313 (supplied).

The stove requires a minimum ceiling height
of 47 1/2" for a rear vent. For temperature
requirements, the space around and above the
stove must be left unobstructed.

5”

BRICK

COMBUSTIBLE

NON-COMBUSTIBLE

45

1

/

2

” MINIMUM

PLUS RISE *

MANTEL, SHELF,

OR CEILING

0” IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.

1”

2”

15

1

/

2

35

1

/

2

51”

2”

The stove requires a minimum ceiling height of
51" for a top vent. For temperature requirements,
the space around and above the stove must be
left unobstructed.

FIGURE 35

Minimum clearance to combustible construction from
stove and vent surfaces:

A

- 2"

B

- 5"

C - 2"

-

1" to bottom and sides of the vent pipe*

-

2" to top of the vent pipe*

Rear

Exit

-

47 1/2" to ceiling from base of the unit

Top

Exit

-

51" to ceiling from base of the unit

MINIMUM CLEARANCES TO COMBUSTIBLES

BACK WALL SIDE W

A

LL

BACK WALL SIDE W

A

LL