Venting applica tion fl o w char t – Napoleon Fireplaces Castlemore GDS26N User Manual

Page 8

Advertising
background image

8

W415-0607 / A / 01.18.08

VENTING APPLICA

TION FL

O

W

CHAR

T

ST

OVE VENT EXIT

REAR EXIT

T

O

P

EXIT

Horizontal T

ermination

V

ertical T

ermination

V

ertical T

ermination

V

ertical rise

is equal to

or greater

than the

horizontal

run

V

ertical rise

is less than

horizontal

run

Horizontal

run + verti-

cal rise to

maximum

of 40 feet

Horizontal

run + verti-

cal rise to

maximum of

24.75 feet

3.5 times the

vertical rise

equal to or

greater than

the horizon-

tal run

Horizontal T

ermination

V

ertical rise

is equal to

or greater

than the

horizontal

run

Horizontal

run + verti-

cal rise to

maximum

of 40 feet

V

ertical rise

is equal to

or greater

than the

horizontal

run

Horizontal

run + verti-

cal rise to

maximum

of 40 feet

V

ertical rise

is equal to

or greater

than the

horizontal

run

Horizontal

run + verti-

cal rise to

maximum

of 40 feet

V

ertical rise

is less than

horizontal

run

Horizontal

run + verti-

cal rise to

maximum

of 40 feet

3 times the

vertical rise

equal to or

greater than

the horizon-

tal run

V

ertical rise

is less than

horizontal

run

Horizontal

run + verti-

cal rise to

maximum of

24.75 feet

4.2 times the

vertical rise

equal to or

greater than

the horizon-

tal run

V

ertical rise

is less than

horizontal

run

Horizontal

run + verti-

cal rise to

maximum

of 40 feet

3 times the

vertical rise

equal to or

greater than

the horizon-

tal run

Advertising