NTI UNIMUX SERIES USB KVM SWITCH

9

MODES OF OPERATION

Basic Command Mode

In order to control the UNIMUX with the keyboard connected, Command Mode must be enabled. To enter Command Mode from
the keyboard:

Press


NOTE: Basic Command mode is only used in a UNIMUX-USBV-2. All other UNIMUX-
USBV-x switches have OSD installed. To control these models, proceed to “OSD
CONTROL” on page 12. If this is a UNIMUX-USBV-2, continue on this page.

When the COMMAND LED is illuminated, all 3 status lights on the keyboard will illuminate (if they aren't already due to caps lock,
scroll lock, and/or num lock) to indicate that Command Mode is enabled and the

following functions are available:

Basic Command

Functions


Function:

Keystroke:



Increment Port



Decrement Port


Toggle Scan Mode
ON and OFF


Toggle Broadcast Mode
ON and OFF

Set scan time-out
period for each port.



Select a specific
port

Configure port to connect
To a MAC CPU


Configure port to connect
To a Windows or SUN
CPU



Exit Command Mode

Scan Mode

To activate or deactivate Scan Mode press <S> while in Command Mode.

When in Scan Mode the switch scans to each port

with a CPU powered-ON. (The SCAN LED on the front panel will illuminate and remain ON while in Scan Mode. ) The port with
the CPU powered-ON remains active while in use until it becomes idle for the configured dwell time (default time-out period is 5
seconds) before switching to the next powered-ON CPU port. See Command Mode section above for configuring the scan dwell
time.

Note: The keyboard and mouse must remain idle for the full scan dwell time before the switch selects the next active
port.

`

+

Ctrl

~

(ACCENT

KEY)

`

CHORDED SEQUENCE- PRESS CONSECUTIVELY
AND KEEP KEYS PRESSED UNTIL ALL ARE PRESSED.

+

-

PRESS CONSECUTIVELY

or

PRESS EITHER KEY

KEY SYMBOLS LEGEND:

Esc

FYI: The user must exit Command Mode to type to a CPU.

To exit Command Mode, either hold down any touch-switch on the
front panel for more than 2 seconds, OR press <ESC> on the
keyboard.

S

(The SCAN Mode LED will
also toggle ON and OFF)

T -

-

(xxx from 002 to 255. ie. T002
would set the time-out period
for 2 seconds)

-

(0-2)
x

(0-9)
x

(0-9)
x

B

(The Broadcast Mode LED
will toggle ON and OFF.)

(select the next
higher port
ex. 01 02)

I

or

or

D

(select the next
lower port
ex. 02 01)

or

or

P -

-

(P0x would be P01 or P02)

x

0

+

M

0

(x= 1or 2 <M> + <0> + <1> will enable function on Port 1
<M> + <0> + <2> will enable function on Port 2. Keyboard
LED's will flash once to confirm command. )

+

x

+

W

0

(x= 1or 2 <W> + <0> + <1> will disable function on Port 1
<W> + <0> + <2> will disable function on Port 2. Keyboard
LED's will flash once to confirm command. )

x

+

Advertising