Unit address and loop back, Command protocol – Network Technologies USBV-x User Manual

Page 31

Advertising
background image

NTI UNIMUX SERIES USB KVM SWITCH

27

Unit Address and Loop Back

To allow multiple units to be controlled from a single CPU serial port, the RS232 control interface is designed to allow "daisy
chaining" up to 15 units. By setting the appropriate RS232 DIP switches, each unit can be given a unique address (1-15). Then
the unit will only respond to commands on the bus if its address is embedded in the command. Use the table below to set the unit
address.

DIP SWITCH

UNIT ADDRESS

8

7

6

5

OFF

OFF

OFF

OFF

0 (not valid)

OFF

OFF

OFF

ON

1

OFF OFF

ON OFF 2

OFF OFF

ON ON

3

OFF ON OFF OFF 4
OFF ON OFF ON 5
OFF ON ON OFF 6
OFF ON ON ON 7
ON OFF

OFF

OFF

8

ON OFF

OFF

ON 9

ON OFF

ON OFF

10

ON OFF

ON ON 11

ON ON

OFF

OFF

12

ON ON

OFF

ON 13

ON ON

ON OFF

14

ON ON

ON ON 15








Figure 29- RS232 connection with Matrix-Y-1 cable



Figure 30- Pinout of Matrix-Y-1 cable

Command Protocol

RS232 commands supported by the unit are defined below. All command strings should be terminated with a <CR> (carriage
return). When a command is sent, the entire string is echoed back along with a response from the addressed unit as shown in the
command definitions. All characters in the command string should be upper case, and all numbers below 10 should have a
leading 0 (ex: 1 = 01). As command strings are sent, the inner character delay cannot exceed 500 milliseconds.












Figure 31- RS232 Communication Illustrated

NTI

SWITCH

CPU

RS232

First Unit

NTI

SWITCH

RS232

NTI

SWITCH

RS232

Second Unit

Last Unit

RS232
Serial Port

Matrix-Y-1

Matrix-Y-1

Matrix-Y-1

(Unit #1)

(Source)

2

3

3

3

5

5

5

2

2

7
8

1
4
6

Jumper

Jumpers

Not connected to
source connector

(Unit #2)

9D Female

9D Male

9D Male

Wiring Schematic of Matrix-Y-1 cable

Note: The "loop back" RS232 DIP switch (RS232 DIP
switch 1) should be ON for the last unit in the chain, and
OFF for all other units. If only one unit is being controlled,
the loop back DIP switch should be left ON.


Note: In order to connect multiple UNIMUX units together
a Matrix-Y-1 cable must be used. (See Fig. 29.) See Fig.
30 for the pinout of the Matrix-Y-1 cable.

CS 01,01,03<CR>

CS 01,01,03<CR>

(COMMAND RECEIVED)

(RESPOND)

* <CR>

(COMMAND SENT)

(RESPONSE RECEIVED)

CS 01,01,03<CR>

* <CR>

CPU

SWITCH AT UNIT ADDRESS 01

RS232

RS232

(ECHO)

CS 01,01,03<CR>