Cabling, Cabling -5, Figure 2-2 – National Instruments 8330 Series User Manual

Page 16: Pxi mxi-3 before installation as secondary -5

Advertising
background image

Chapter 2

Installation

© National Instruments Corporation

2-5

PXI-PCI 8330 Series User Manual

Figure 2-2 shows a PXI MXI-3 card just before installation in the system
controller slot of a National Instruments PXI-1000 mainframe.

Figure 2-2. PXI MXI-3 Before Installation as Secondary

Cabling

1.

Connect the appropriate serial cable to both primary and secondary
MXI-3 cards. If you are using a fiber-optic cable, be sure to remove the
protective caps from the connectors.

Caution

Do not remove the cable after the system is powered on. Doing so may crash

the system.

2.

Turn on the system containing your secondary MXI-3 card.

3.

Turn on the system containing your primary MXI-3 card.

For more information on cables, see the

MXI-3 Cable Options

section in

Chapter 3,

Hardware Overview

.

8

7

6

5

4

3

2

1

ON

STANDBY

PXI/CompactPCI Chassis

Ejector Handle

in Down Position

PXI/CompactPCI Slot 1

PXI MXI-3

Advertising