Set the device id (device id) – Roland TD-6 User Manual

Page 101

Advertising
background image

101

Chapter 7 Making the MIDI Settings (SETUP/MIDI, BULK DUMP)

7

Mixing MIDI Signals Coming to the

MIDI IN with Real Time Performance

on the Pads (Soft Thru)

This setting causes data (except for System Exclusive
messages) received at MIDI IN to be output from the MIDI
OUT/THRU connector along with the pad and sequencer
performance data.

fig.07-016a.e

If this setting is not used, leave it “OFF” as the trigger
response of the pads will be faster.

fig.07-017_50

Soft Thru: OFF, ON

OFF:

Only pad and sequencer performance data is output from the
MIDI OUT/THRU connector.

ON:

Data received at MIDI IN is output together with the pad and
sequencer performance data from the MIDI OUT/THRU
connector.

Set the Device ID (Device ID)

The setting described here is necessary only when you wish to
transmit separate data to two or more TD-6 units at the same
time. Do not change this setting in any other case.

At the factory settings, the device ID is set to “17.”

Example:

When saving data using Bulk Dump (p. 103), save using “17”
as the TD-6 Device ID. When re-transmitting this data back to
the TD-6, it won’t receive if the Device ID is set to something
other than “17.” Even if you happen to have another TD-6
connected, data will not be received if the Device ID is set to
something other than “17.”

fig.07-018.e (ID 16 17)

If you lose track of the Device ID setting that was used when
saving data via a bulk dump, it will no longer be possible to
reload the bulk data that was saved.

fig.07-019_50

Device ID: 1–32

External MIDI Sequencer

TD-6

Pad

Soft Thru: ON

MIDI Compatible Pad

OUT/THRU

OUT

IN

Trigger

Input

TD-6

Device ID: 17

Not Received

MIDI IN

MIDI OUT

Transmit Data (Device ID:17)

TD-6

Device ID: 16

MIDI IN

External MIDI Sequencer

Advertising