System realtime messages, System exclusive messages, Universal non-realtime system exclusive messages – Roland TD-6 User Manual

Page 142: Global parameter control, Data transmission, Active sensing

Advertising
background image

142

MIDI Implementation

System exclusive messages related to mode
setting

Turn General MIDI System On

This is a command message that resets the internal settings of the unit to the
General MIDI initial state (General MIDI System - Level 1). After receiving this
message, this unit will automatically be set to the proper condition for correctly
playing a General MIDI score.

Status

Data byte

Status

F0H

7EH, 7FH, 09H, 01H

F7H

Byte

Explanation

F0H

Exclusive status

7EH

ID number (Universal Non-realtime Message)

7FH

Device ID (Broadcast)

09H

Sub ID#1 (General MIDI Message)

01H

Sub ID#2 (General MIDI On)

F7H

EOX (End Of Exclusive)

*

Not Received when SETUP/MIDI COMMON/Rx GM ON is set to
"OFF".(Initial Value is ON)

*

There must be an interval of at least 50 ms between this message and the next.

Turn General MIDI System Off

When a "GM System Off" is received, the TD-6 is switched to normal mode.

Status

Data byte

Status

F0H

7EH, 7FH, 09H, 02H

F7H

Byte

Explanation

F0H

Exclusive status

7EH

ID number (Universal Non-realtime Message)

7FH

Device ID (Broadcast)

09H

Sub ID#1 (General MIDI Message)

02H

Sub ID#2 (General MIDI Off)

F7H

EOX (End Of Exclusive)

*

Not Received when SETUP/MIDI COMMON/Rx GM ON is set to
"OFF".(Initial Value is ON)

*

There must be an interval of at least 50 ms between this message and the next.

Universal Non-realtime System Exclusive
Messages

Identity Request

*

Regarding the Identity Request refer to page 137.

Global Parameter Control

Channel Pressure

Status

Data byte

Status

F0H

7FH, dev, 09H, 01H, 0nH, ppH, rrH

F7H

Byte

Explanation

F0H

Exclusive status

7FH

ID number (Universal Realtime Message)

dev

Device ID (dev: 00H - 1FH Initial value is 10H (17))

09H

Sub ID#1 (Controller Destination Setting)

01H

Sub ID#2 (Channel Pressure)

0nH

MIDI channel (00H - 0FH)

ppH

parameter

rrH

range

F7H

EOX (End Of Exclusive)

pp=0

Pitch Control

rr=28H-58H

-24 - +24 semitones

pp=1

Filter Cutoff Control

rr=00H-7FH

-9600 - +9450 cents

pp=2

Amplitude Control

rr=00H-7FH

0 - 200 %

pp=3

LFO Pitch Depth

rr=00H-7FH

0 - 600 cents

pp=4

LFO Filter Depth

rr=00H-7FH

0 - 2400 cents

pp=5

LFO Amplitude Depth

rr=00H-7FH

0 - 100 %

*

Even if the Device ID is 7FH (Broadcast), Identity Reply message will be
transmitted.

*

In the rhythm part (ch.10), ignored this message.

Data transmission

Request data 1 RQ1 (11H)

*

Regarding the RQ1 refer to page 137.

Data set 1 DT1 (12H)

*

Regarding the DT1 refer to page 138.

Section 2. Transmit data

*

When SETUP/MIDI COMMON/Soft Thru is set to "ON", messages received in
addition to the following messages are also sent.

System Realtime Messages

Active sensing

Status
FEH

*

This will be transmitted constantly at intervals of approximately 250 ms.

System Exclusive Messages

Universal Non-realtime System Exclusive
Messages

Identity Reply

*

Regarding the Identity Reply refer to page 139.

Data Transmission

Data set 1 DT1 (12H)

*

Regarding the DT1 refer to page 138.