System realtime messages, System exclusive messages, Universal non-realtime system exclusive messages – Roland TD-6 User Manual

Page 142: Global parameter control, Data transmission, Active sensing

Advertising
background image

142

MIDI Implementation

●

System exclusive messages related to mode
setting

❍

Turn General MIDI System On

This is a command message that resets the internal settings of the unit to the
General MIDI initial state (General MIDI System - Level 1). After receiving this
message, this unit will automatically be set to the proper condition for correctly
playing a General MIDI score.

Status

Data byte

Status

F0H

7EH, 7FH, 09H, 01H

F7H

Byte

Explanation

F0H

Exclusive status

7EH

ID number (Universal Non-realtime Message)

7FH

Device ID (Broadcast)

09H

Sub ID#1 (General MIDI Message)

01H

Sub ID#2 (General MIDI On)

F7H

EOX (End Of Exclusive)

*

Not Received when SETUP/MIDI COMMON/Rx GM ON is set to
"OFF".(Initial Value is ON)

*

There must be an interval of at least 50 ms between this message and the next.

❍

Turn General MIDI System Off

When a "GM System Off" is received, the TD-6 is switched to normal mode.

Status

Data byte

Status

F0H

7EH, 7FH, 09H, 02H

F7H

Byte

Explanation

F0H

Exclusive status

7EH

ID number (Universal Non-realtime Message)

7FH

Device ID (Broadcast)

09H

Sub ID#1 (General MIDI Message)

02H

Sub ID#2 (General MIDI Off)

F7H

EOX (End Of Exclusive)

*

Not Received when SETUP/MIDI COMMON/Rx GM ON is set to
"OFF".(Initial Value is ON)

*

There must be an interval of at least 50 ms between this message and the next.

●

Universal Non-realtime System Exclusive
Messages

❍

Identity Request

*

Regarding the Identity Request refer to page 137.

●

Global Parameter Control

❍

Channel Pressure

Status

Data byte

Status

F0H

7FH, dev, 09H, 01H, 0nH, ppH, rrH

F7H

Byte

Explanation

F0H

Exclusive status

7FH

ID number (Universal Realtime Message)

dev

Device ID (dev: 00H - 1FH Initial value is 10H (17))

09H

Sub ID#1 (Controller Destination Setting)

01H

Sub ID#2 (Channel Pressure)

0nH

MIDI channel (00H - 0FH)

ppH

parameter

rrH

range

F7H

EOX (End Of Exclusive)

pp=0

Pitch Control

rr=28H-58H

-24 - +24 semitones

pp=1

Filter Cutoff Control

rr=00H-7FH

-9600 - +9450 cents

pp=2

Amplitude Control

rr=00H-7FH

0 - 200 %

pp=3

LFO Pitch Depth

rr=00H-7FH

0 - 600 cents

pp=4

LFO Filter Depth

rr=00H-7FH

0 - 2400 cents

pp=5

LFO Amplitude Depth

rr=00H-7FH

0 - 100 %

*

Even if the Device ID is 7FH (Broadcast), Identity Reply message will be
transmitted.

*

In the rhythm part (ch.10), ignored this message.

●

Data transmission

❍

Request data 1 RQ1 (11H)

*

Regarding the RQ1 refer to page 137.

❍

Data set 1 DT1 (12H)

*

Regarding the DT1 refer to page 138.

Section 2. Transmit data

*

When SETUP/MIDI COMMON/Soft Thru is set to "ON", messages received in
addition to the following messages are also sent.

■

System Realtime Messages

●

Active sensing

Status
FEH

*

This will be transmitted constantly at intervals of approximately 250 ms.

■

System Exclusive Messages

●

Universal Non-realtime System Exclusive
Messages

❍

Identity Reply

*

Regarding the Identity Reply refer to page 139.

●

Data Transmission

❍

Data set 1 DT1 (12H)

*

Regarding the DT1 refer to page 138.

Advertising