Figure 4-8 . keystone correction, 8. keystone correction, Figure 4-8 – Runco CINEWIDETM VX-3000D User Manual

Page 96: Pre l iminar y

Advertising
background image

Operation

80

VX-3000d Series Installation/Operation Manual

PRE

L

IMINAR

Y

Figure 4-8. Keystone Correction

Lens: Select Lens from the Display Device - Configure menu to access the motorized

lens controls. Refer to Primary Lens Adjustments on page 50.

Lamp Info.: Select Lamp Info. from the Display Device - Configure menu to obtain

information about the currently-installed lamp: its serial number and number of hours in
use.

Lamp Hours Reset: When you replace the projector lamp (refer to Lamp

Replacement on page 85), you should also reset the lamp hour counter to zero so
that the lamp usage information in the Lamp Info. window is accurate. To do this, select
Lamp Hours Reset from the Display Device - Configure menu. A confirmation dialog
box appears. Select “Yes” to continue with the reset or “No” to cancel the operation.

Positive values

compress top.

Negative values

compress bottom.

-

+

Vertical Keystone Correction

Positive values

compress right side.

Negative values

compress left side.

-

+

Horizontal Keystone Correction

Projector

Projected Image