Transmission Protocol Description

After Power-ON the PE (Paper Empty) signal is set to low level and the SELECT

and ¯¯¯¯¯

FAULT

signals are set to high level.

The printer is now ON-LINE and ready to receive data.

Timing

The host sets a print/control character to the 8 data lines.

After a time delay of a minimum of 0.5 µs, the host sends a ¯¯¯¯¯¯

STROBE

pulse of a

minimum of 0.5 µs. When the data byte is accepted into the interface buffer the

printer transmits a BUSY signal and an ¯¯¯¯

ACKN

pulse.

The ¯¯¯¯

ACKN

pulse informs the host that the data has been received and that the

printer is ready to receive new data.

If the interface buffer is full except for the last character the BUSY is not reset in

order to stop the data transfer from the host. The BUSY signal is only reset if

space is available in the interface buffer for a minimum of 512 characters.

While the printer is offline, or a serial interface is active BUSY remains high and

no ¯¯¯¯

ACKN

is sent until the printer enters online state or the serial interface is

deselected.