Barcode programming examples, 2 of 5 industrial, Code 39 – Output Solutions C I - 8 0 6 0 User Manual

Page 236

Advertising
background image

Appendix F Barcode Quick Reference

F-5

2.2

Barcode Programming Examples

Note:

All examples are coded in standard uni-directional printing - that means the

parameter "P " is not used.

7

In the following examples, 8 stands for "Space".

The small square before and after the printed barcode indicates the

actual print position.

Between Start Barcode and Stop Barcode are only printable characters

tolerated (no CR or LF).

Barcode Example for Code 39

Barcode Header:

ESC [ ; P ; P ; P ; P ; P ; P 8 z

2

3

4

5

6

7

ESC [ ; 201 ; 8 ; 1 ; 1 ; 1 ; 8 z

Start Barcode:

ESC [ ? 0 h

Data:

* C 8 O 8 D 8 E 8 8 8 3 9 *

Stop Barcode:

ESC [ ? 0

l

Barcode Example for 2 of 5 Industrial

Barcode Header:

ESC [ ; P ; P ; P ; P ; P ; P 8 z

2

3

4

5

6

7

ESC [ ; 202 ; 8 ; 1 ; 1 ; 1 ; 8 z

Start Barcode:

ESC [ ? 0 h

Data:

: 1 2 3 4 5 6 7 8 9 0 ;

Stop Barcode:

ESC [ ? 0

l