7.11 Setting Periodic Printout On/Off

The contents of the periodic printout can be selected from the following three:

ON1: Date/time, measured values, scale, and chart-feeding speed are printed.
ON2: Date/time and chart-feeding speed are printed.
OFF: No printout.

The default is set to ‘ON1’.
The relationship between the chart-feeding speed and the periodic printout interval is as
shown below.

Every 8 hours
Every 4 hours
Every 2 hours
Every 1 hour
Every 30 minutes
Every 20 minutes
Every 10 minutes
No printout

10 to 15mm/h
20 to 30mm/h
40 to 60mm/h
75 to 120mm/h
150 to 180mm/h
200 to 300mm/h
360 to 1500mm/h
1800mm/h or more

Chart Speed

Pen Model

Periodic Printout Interval

Every 8 hours
Every 4 hours
Every 2 hours
Every 1 hour
No printout

10 to 15mm/h
20 to 30mm/h
40 to 75mm/h
80 to 100mm/h
120mm/h or more

Chart Speed

Dot-printing Model

Periodic Printout Interval

SETTING PROCEDURE:
Enter the SET UP mode by turning ‘ON’ the power while pressing and holding the [CH
UP]
(

ENT) key until the SET UP display appears.

Use the [

] key to select the display [

]. Press the [ENT] key.

Use the [

] key to select the display [

]. Press the [ENT] key.

Select ‘ON1’, ‘ON2’or ‘OFF’ using the [

] key. Press the [ENT] key.

The display [

] appear.

Before leaving the SET UP mode, you have to store your new settings. Use the [

] key

to select the [

] display, and press the [ENT] key.

Select [

] to keep your new settings or [

] to abort the settings, and

press the [ENT] key. After a few seconds, the OPERATION mode will appear.

NOTE

If set, this printout appears on the chart with a certain regularity.