3.4

CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE

To configure, attach the NMM to a DB-9 serial (RS-232) equipped computer with terminal emulation
software such as HyperTerminal. Using a standard serial cable, connect the serial port of the PC and the
Serial Console Port of the NMM. This is a standard asynchronous DCE serial interface. The pin-outs are
illustrated below.

1

6

5

9

2
3
5
7

DB-9 Female

RD

TD

GND

RTS

Serial Connector Pin Outs

Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window.

Set the PC’s serial port to the following:

Bits Per Second:

57,600

Stop Bits:

1

Data Bits:

8

Parity:

NONE

Hardware Flow Control:

NONE

Power the chassis containing the NMM and press <ENTER> to bring up a command line prompt on the
attached PC.

The module is configured with the following defaults:

IP

IP Address:

192.168.1.220

IP Subnet Mask:

255.255.255.0

Passwords

Serial:

No password assigned

FTP:

No password assigned

Telnet:

public

SNMPv1/v2c Communities

READ:

public

WRITE:

public

SNMPv3 Parameters

User 1 name (read only):

guest

User 2 name (read/write):

admin

User 1 Privacy pwd:

publicguest

User 1 Authen pwd:

publicguest

User 2 Privacy pwd:

privateadmin

User 2 Authen pwd:

privateadmin