OVERVIEW:

The

iConverter

fiber-to-fiber chassis plug-in media

converters provide single-mode (SM) to multimode (MM),

dual fiber to single-fiber, wavelength conversion and fiber

extension. Fixed-fiber models are available for Ethernet,

Fast Ethernet, Gigabit Ethernet and SONET/SDH

applications. The Small Form Pluggable (SFP) model

is protocol transparent and also supports Fibre Channel.
The

iConverter

FF media converters can be used in a

managed or unmanaged configuration. Management

of the FF is accomplished by installing a Management

Module

1

(such as an

iConverter

NMM2 or 10/100M2) in

the same chassis. Management provides monitoring,

configuration and trap notification. When unmanaged,

it can be installed in a chassis without a Management

Module.

1

For complete management support, use a M2 series module

(NMM2, GX/TM2, 2GXM2, 10/100M2, 2FXM2) or higher. The xFF
(8699-0) module must be at rev xx/09 or greater. All revisions of
FF modules are supported.

iConverter

®

100FF, OC3FF, OC12FF, 1000FF and xFF

Fiber-to-Fiber Converter Plug-in Module

User Manual

Port 1 (P1)

Port 2 (P2)

iConverter 1000FF Dual Fiber Modules

Connector

SC/SC

Fiber Type

(Port 1

Port 2)

Distances

(Port 1

Port 2)

Tx

Wavelength

(nm)

Rx Wavelength

(nm)

8642-0

MM

220/550m

1

850

850

MM

220/550m

1

850

850

8642-1

MM

220/550m

1

850

850

SM

12km

1310

1310

8642-2

MM

220/550m

1

850

850

SM

34km

1310

1310

8642-3

MM

220/550m

1

850

850

SM

80km

1550

1550

8643-2

SM

12km

1310

1310

SM

34km

1310

1310

8643-3

SM

12km

1310

1310

SM

80km

1550

1550

ST/SC

iConverter 1000FF Single-Fiber Modules

8650-1

MM

220/550m

1

850

850

SM SF

20 km

1310

1550

8651-1

MM

220/550m

1

850

850

SM SF

20 km

1550

1310

8652-1

SM

12 km

1310

1310

SM SF

20 km

1310

1550

8653-1

SM

12 km

1310

1310

SM SF

20 km

1550

1310

8650-2

MM

220/550m

1

850

850

SM SF

40 km

1310

1550

8651-2

MM

220/550m

1

850

850

SM SF

40 km

1550

1310

8652-2

SM

12 km

1310

1310

SM SF

40 km

1310

1550

8653-2

SM

12 km

1310

1310

SM SF

40 km

1550

1310

1

62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm

multimode fiber up to 550m. Refer to the fiber cable manufacturer for

multimode distance specifications.

iConverter 100FF Dual Fiber Modules

Connector

Fiber Type

(Port 1

Port 2)

Distances

(Port 1

Port 2)

Tx

Wavelength

(nm)

Rx

Wavelength

(nm)

ST/ST

SC/SC

8620-1

8622-1

MM

5km

1310

1310

SM

30km

1310

1310

8620-2

8622-2

MM

5km

1310

1310

SM

60km

1310

1310

-

8622-3

MM

5km

1310

1310

SM

120km

1550

1550

ST/SC

SC/SC

iConverter 100FF Single-Fiber Modules

8630-1

8634-1

MM

5 km

1310

1310

SM SF

20 km

1310

1550

8631-1

8635-1

MM

5 km

1310

1310

SM SF

20 km

1550

1310

8630-2

8634-2

MM

5 km

1310

1310

SM SF

40 km

1310

1550

8631-2

8635-2

MM

5 km

1310

1310

SM SF

40 km

1550

1310

8632-1

8636-1

SM

30 km

1310

1310

SM SF

20 km

1310

1550

8633-1

8637-1

SM

30 km

1310

1310

SM

20 km

1550

1310

8632-2

8636-2

SM SF

30 km

1310

1310

SM

40 km

1310

1550

8633-2

8637-2

SM

30 km

1310

1310

SM SF

40 km

1550

1310

iConverter OC12FF Dual Fiber Modules

Connector

SC/SC

Fiber Type

(Port 1

Port 2)

Distances

(Port 1

Port 2)

Tx

Wavelength

(nm)

Rx

Wavelength

(nm)

8681-1

MM

220/550m

1

1310

1310

SM

12km

1310

1310

8681-2

MM

220/550m1

1310

1310

SM

34km

1310

1310

8681-3

MM

220/550m

1

1310

1310

SM

80km

1550

1550

SC/SC

iConverter OC12FF Single-Fiber Modules

8690-1

MM

220/550m

1

1310

1310

SM SF

20 km

1310

1550

8691-1

MM

220/550m

1

1310

1310

SM SF

20 km

1550

1310

8692-1

SM

12 km

1310

1310

SM SF

20 km

1310

1550

8693-1

SM

12 km

1310

1310

SM SF

20 km

1550

1310

1

62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm

multimode fiber up to 550m. Refer to the fiber cable manufacturer for

multimode distance specifications.

iConverter OC3FF Dual Fiber Modules

Connector

Fiber Type

(Port 1

Port 2)

Distances

(Port 1

Port 2)

Tx

Wavelength

(nm)

Rx

Wavelength

(nm)

ST/ST

SC/SC

8660-1

8661-1

MM

5km

1310

1310

SM

30km

1310

1310

8660-2

8661-2

MM

5km

1310

1310

SM

60km

1310

1310

8661-3

MM

5km

1310

1310

SM

120km

1550

1550

ST/SC

SC/SC

iConverter OC3FF Single-Fiber Modules

8670-1

8674-1

MM

5 km

1310

1310

SM SF

20 km

1310

1550

8671-1

8675-1

MM

5 km

1310

1310

SM SF

20 km

1550

1310

8670-2

8674-2

MM

5 km

1310

1310

SM SF

40 km

1310

1550

8671-2

8675-2

MM

5 km

1310

1310

SM SF

40 km

1550

1310

8672-1

8676-1

SM

30 km

1310

1310

SM SF

20 km

1310

1550

8673-1

8677-1

SM

30 km

1310

1310

SM SF

20 km

1550

1310

8672-2

8676-2

SM

30 km

1310

1310

SM SF

40 km

1310

1550

8673-2

8677-2

SM

30 km

1310

1310

SM SF

40 km

1550

1310

iConverter xFF Dual Fiber Modules

Connector

SFP

Fiber Type

(Port 1

Port 2)

Distances

(Port 1

Port 2)

Tx

Wavelength

(nm)

Rx Wavelength

(nm)

8699-0

-

-

-

-

-

-

-

-

Refer to the SFP data sheet for supported transceivers.

Page 7

Page 8

Page 9

Page 10

Page 11

Page 12

LINK MODES:

The

iConverter

fiber-to-fiber media converters support two

different linking modes.

Fig. 1 Link Modes

In Link Propagate (LP) mode (sometimes referred to as

Link Loss Carry Forward), a port transmits a Link signal

only when receiving a Link on the other front-plane port,

and a loss of a received Link at one port causes the other

front-plane port to stop transmitting its link signal. For

example, P1 transmits a Link only when receiving a Link

at P2 [Fig 1(a)].
In Remote Fault Detection (RFD) mode, a port transmits

a Link signal only when both itself and the other port are

receiving Link signals. A loss of a received Link signal at

a port is Looped-back and the port stops transmitting a

Link signal. The same loss of Link is propagated to the

other port which also stops transmitting the Link signal.

For example, the loss of Link into P2 causes both P1 and

P2 ports to stop transmission of the Link signal [Fig 1(b)].
Note: Connecting two adjacent converters which

are both set to RFD is not permitted and will cause a

“deadly embrace” lockup.

Form: 040-08600-002O 5/14

FRONT PANEL DIP-SWITCH SETTINGS:

Left / Down

Right / Up

Fig. 2 Front Panel Dip-Switches

Link Segment/Link Propagation “LS/LP” Dip-Switch:

This DIP-Switch has no effect. The LS function of this DIP-

Switch has been disabled to enhance compatibility with

third-party fiber optic devices.

iConverter

fiber-to-fiber media

converters normally operate in LP mode.
Remote Fault Detection Switch “RFD” Dip-Switch:

When in the Remote Fault Detection “RFD” position, the

Remote Fault Detection mode is enabled and LP mode

is disabled. When in the Normal “Norm” position (fac-

tory setting), Remote Fault Detection is disabled and LP

mode is enabled.

LED INDICATORS:

LED

Color Description

Pwr:

Yellow On--Power on

Lk/Rx (P1): Green On--Link Off--No Link

Lk/Rx (P2): Green On--Link Off--No Link

Warning

The operating description in this Instruction Manual is for

use by qualified personnel only. To avoid electrical shock,

do not perform any servicing of this unit other than that

contained in the operating instructions, unless you are

qualified and certified to do so by Omnitron Systems

Technology, Inc.

Warranty

This product is warranted to the original purchaser against

defects in material and workmanship for a period of 2

YEARS from the date of shipment. A LIFETIME limited

warranty may be obtained by the original purchaser by

REGISTERING this product with Omnitron within 90

days from the date of shipment. To register, complete

and mail or fax the enclosed Registration Card to the

indicated address. You may also register your product

on the internet at www.omnitron-systems.com/Register.

During the warranty period, Omnitron will, at its option,

repair or replace a product which is proven to be defective.
For warranty service, the product must be sent to an

Omnitron designated facility, at Buyer’s expense. Omnitron

will pay the shipping charge to return the product to Buyer’s

designated US address (within the 48 contiguous states

and the District of Columbia) using Omnitron’s standard

shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting

from improper or inadequate use and/or maintenance

of the equipment by Buyer, Buyer-supplied equipment,

Buyer-supplied interfacing, unauthorized modifications

or tampering with equipment (including repairs of

equipment by personnel not specifically authorized and

certified by Omnitron, or misuse, or operating outside the

environmental specification of the product (including but not

limited to voltage, ambient temperature, radiation, unusual

dust, etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron

specifically disclaims the implied warranties of

merchantability and fitness for any particular purpose.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and

exclusive remedies. Omnitron shall not be liable for any

direct, indirect, special, incidental, or consequential

damages, whether based on contract, tort, or any legal

theory.

Technical Support:
For help with this product, contact our Technical Support:
Phone:

(949) 250-6510

Fax:

(949) 250-6514

Address: Omnitron Systems Technology, Inc.

38 Tesla

Irvine, CA 92618 USA

E-mail:

[email protected]

URL:

www.omnitron-systems.com

MOUNTING AND CABLE ATTACHMENT:

iConverter

modules are hot-swappable and can be

installed into any chassis in the

iConverter

family.

1. Carefully slide the

iConverter

module into installation

slot, aligning the module with the installation guides.

NOTE: Ensure that the module is firmly seated against

backplane.

2. Secure the module by securing the panel fastener

screw (attached to module) to chassis front.

3. When using an SFP model (8699-0), insert the SFP

Fiber transceivers into the SFP receptacles on the

module.

Note: The release latch of the SFP Fiber transceiver

must be in the closed position before insertion. The

transceivers installed must have matching speeds

to operate.

4. Attach an appropriate multimode or single-mode fiber

cable to each fiber connector. The transmit cable (Tx)

must attach to the receive side on the other device; the

receive cable (Rx) must attach to the transmit.

5. When using single-fiber (SF) models, the Tx wavelength

on one end must match the Rx wavelength on the other

and the converters must be used in matched pairs

(example: model 8670-1 must be matched with model

8671-1).

SPECIFICATIONS:

Model Type

100FF

1000FF

OC3FF

OC12FF

xFF

Protocols

100BASE-FX,

100BASE-BX,

100BASE-LX

1000BASE-SX,

1000BASE-LX,

1000BASE-ZX,

1000BASE-BX

OC-3

OC-12

100BASE-FX,

1000BASE-X,

OC-3, OC-12

Fibre Channel

Maximum

Data Rate

155Mbps

1.25Gbps

155Mbps

1.25Gbps

4.25Gbps

Fiber

Connectors

SC, ST,

Single-Fiber

SC

SC,

Single-Fiber

SC

SC, ST,

Single-Fiber

SC

SC,

Single-Fiber

SC

SFP

Controls

Link Propagate, Remote Fault Detection

LED

Displays

Power,

Fiber Optic Link (2)

Dimensions

W:0.85" x D:4.5" x H:2.8"

Weight

8 oz.

Compliance

UL, CE, FCC Class A,

NEBS Level 3

Power

Requirement

(typical)

0.5A @

3.3VDC

0.5A @

3.3VDC

0.5A @

3.3VDC

0.5A @

3.3VDC

0.5A @

3.3VDC

Temperature

Standard: 0 to 50º C

Wide: -40 to 60º C

Storage: -40 to 80º C

Humidity

5 to 95%

(non-condensing)

Altitude

-100m to 4000m

MTBF (hrs)

1,300,000

(a)

(b)

Switch 1

LED Status depends on connected device

Converter A

Converter B

Switch 2

LP

LP

LED Lit

LED Off

Switch 1

Converter A

Converter B

Switch 2

LP

RFD