PRODUCT OVERVIEW
This document describes the basic installation

and configuration of the 2-Port SFP to SFP GM3

standalone modules.
For more information including the complete User

Manual on the 2-Port SFP to SFP GM3 modules,

access Omnitron’s registration page and register

the product:

http://www.omnitron-systems.com/forms/product_registration.php

INSTALLATION PROCEDURE
1) Configure DIP-Switches
2) Install Standalone Module and Connect Cables
3) Configure Module via Command Line Interface
4) Verify Operation

1) CONFIGURE DIP-Switches
DIP-SWITCH BANK 1

SW1 and SW2: P1 and P2 AUTO/MANUAL NEGOTIATION “AN / Man”
When this DIP-switch is in the “AN”

position (factory default), the port

automatically determines the duplex

and pause modes of the connected

device. If the connecting device cannot

provide the proper signal to indicate its

own mode of operation, the DIP-switch

should be set to the “Man” position.

When in manual mode, no capabilities

are advertised and the port operates in

full-duplex mode.

Figure 1: DIP-switch Location

NOTE: If 1000Mbps fiber transceivers are installed, the port always operates in 1000Mbps

full-duplex mode.
NOTE: If 100Mbps fiber transceivers are installed, the port will operate in 100Mbps full-duplex

manual mode.

4) VERIFY OPERATION
Once the module has been installed and configured per steps 1 - 3, verify the module is

operational by viewing the LED indicators.

LED Function

“Legend”

Color

OFF State

ON/Blinking State

Power

“PWR”

Green

No power

ON: Module has power

P1 Link Activity

“100”

Green

Port not linked at 100M

ON: Port linked at 100M

Blinking: Data activity

P1 Link Activity

“1000”

Green

Port not linked at 1000M

ON: Port linked at 1000M

Blinking: Data activity

P1 Link Activity

“100” and “1000”

Green

Port not linked at 10M

ON: Port linked at 10M

Blinking: Data activity

Test/Alarm

“Tst/Alm”

Green

Reserved

Reserved

Management Mode

“Msr/Slv”

Green

N/A

ON: Master (normal)

5 Hz Blinking: Secure Slave

P2 Link Activity

“100”

Green

Port not linked at 100M

ON: Port linked at 100M

Blinking: Data activity

P2 Link Activity

“1000”

Green

Port not linked at 1000M

ON: Port linked at 1000M

Blinking: Data activity

P2 Link Activity

“100” and “1000”

Green

Port not linked at 10M

ON: Port linked at 10M

Blinking: Data activity

Figure 4: LED Indicators

040-8999P-001A 6/09

Page 1

Omnitron Systems Technology * 140 Technology Dr. #500 * Irvine, CA 92618

949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com

Advertising