Omnitron Systems Technology iConverter T3/E3 Plugin Module User Manual

Iconverter, T3/e3 plugin module user manual

Advertising
background image

iConverter

®

T3/E3 Plugin Module USER MANUAL

The

iConverter

T3/E3 media converter provides standard T3 (44.736Mbps) or E3

(34.368Mbps) coax to fiber conversion and can be used to connect to devices such

as PBXs, multiplexers, routers and video servers via fiber. T3/E3 media converters

operate in pairs, extending distances over

fiber, which improves noise immunity,

quality of service, intrusion protection and

network security.
The T3/E3 supports Small Form Pluggable

(SFP) transceivers, enabling adaptability

to different fiber types, distances and

wavelengths, providing maximum flexibility

across a variety of network architectures

and topologies.
Management of the plug-in module is
accomplished by using a Management Module

1

(such as an

iConverter

NMM2 or

10/100M2) that provides monitoring, configuration and trap notification.

INSTALLATION PROCEDURE

1) Configure DIP-Switches
2) Install Module in the Chassis and Connect Cables
3) Verify Operation

1) CONFIGURE DIP-SWITCHES
FRONT PANEL DIP-SWITCHES

“FLB” - Fiber Loopback
This DIP-switch facilitates the testing of the

fiber cables. When the “FLB” DIP-switch is

in the ON position, it sets the fiber port to

a Local Fiber Loopback Mode (Figure B)

and the “FLB” LED is turned on. When in

this mode, data received at the Fiber-In is

forwarded to the BNC-Out and the Fiber-

Out. If no data is received at Fiber-In, an AIS

pattern is transmitted out both BNC-Out and

Fiber-Out. By returning the DIP-switch to

the OFF position, the unit resumes normal

operation.

Figure B: Fiber Loopback and DIP-Switch Settings

d. Connect an appropriate multimode or single-mode fiber cable to the fiber port of the

installed module. It is important to ensure that the transmit (TX) is attached to the

receive side of the device at the other end and the receive (RX) is attached to the

transmit side. Single-fiber (SF) media converter models operate in pairs. The TX

wavelength must match the RX wavelength at the other end and the RX wavelength

must match the TX wavelength at the other end.

3) VERIFY OPERATION

Once the module has been installed and configured per steps 1 and 2, verify the module

is operational by viewing the LED indicators.
The Power LED indicates the module is receiving power.
The Fiber Optic link LED indicates the fiber optic connection has been established.
The Coax LED indicates a T3/E3 signal has been detected.

Form 040-08740-002C 9/13

Omnitron Systems Technology * 38 Tesla * Irvine, CA 92618

949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com

Figure A: DIP-Switch Location

Function

"Legend"

Color

OFF State

ON / Blinking state

Power

"Pwr"

Amber No Power

On: Power available

Fiber Activity

"Act"

Green No valid data

Fast blink (10Hz): Data Received

Fiber AIS

"AIS"

Amber

--

Fast blink (10Hz): AIS Received.

Fiber Test detected

"TST"

Amber No Test Data

Received

Local unit asserting Remote Loopback:

Fast blink (10Hz): Test pattern received.

Slow blink (1 Hz): Unexpected pattern received.

Special Case:

Three quick blinks (2Hz) and pause (1sec.):

Illegal dip-switch selection.

Fiber Loopback

"FLB"

Amber Normal

ON: Local Fiber Loopback.

If "CLB" also "ON" indicates that the unit is the

Local Unit in Remote Loopback Mode.

Slow blink (1Hz) and also "CLB" in slow blink:

indicates that the unit is the Remote Unit in

Remote Loopback Mode.

Coax Loopback

"CLB"

Amber Normal

ON: Local Coax Loopback.

If "FLB" also "ON" indicates that the unit is the

Local Unit in Remote Loopback Mode.

Slow blink (1Hz) and also "FLB" in slow blink:

indicates that the unit is the Remote Unit in

Remote Loopback Mode.

Coax Activity

"ACT"

Green No valid data

Fast blink (10Hz): Data Received

Coax AIS detected

"AIS"

Amber

--

Fast blink (10Hz): AIS Received.

Coax PRBS detected

"PRBS"

Amber

--

Blink 10 Hz: PRBS Received.

Blink 1 Hz: Forcing PRBS onto BNC-Out.

1

For complete management support, use a M2 series module (NMM2, GX/TM2, 2GXM2, 10/100M2,

2FXM2) or higher. The T3/E3 SFP (8759-0) module must be at rev xx/10 or greater.