PRODUCT OVERVIEW
This document describes the basic installation and configuration of the 3-Port GM4 standalone

modules.
The GM4 features one or two SFP ports, one or two UTP ports and a RS-232 Serial Console

Port. The SFP ports support SERDES 100/1000BASE-X SFP fiber and Omnitron approved

SGMII 10/100/1000BASE-T copper transceivers.
NOTE: When using third party 100BASE-FX and unapproved SGMII SFPs, the port must

be manually configured using the Command Line Interface (CLI). Interface settings can be

changed using the portattribute command. For more information including the complete

User Manual on the 3-Port GM4 modules, access Omnitron’s registration page and register

the product:
http://www.omnitron-systems.com/forms/product_registration.php
INSTALLATION PROCEDURE
1) Configure DIP-Switches
2) Install Standalone Module and Connect Cables
3) Configure Module via Command Line Interface
4) Verify Operation

1) CONFIGURE DIP-Switches
DIP-SWITCH BANK 1
The function of DIP-switch Bank 1 is outlined in Figure 1 below.

Switch Position

Legend

Down (Default)

Up

1

P1 AN/MAN

AN

MAN

2

P2 AN/MAN

AN

MAN

3

P3 AN/MAN

AN

MAN

4

Port Redundancy (See Figure 3)

5
6

Link Modes (See Figure 4)

7
8

Figure 1: DIP-switch Bank 1

The location of the DIP-switch is illustrated in Figure 2 on the next page.
SW1 - SW3: P1, P2 and P3 AUTO/MANUAL NEGOTIATION “AN/MAN”
When these DIP-switches are in the Down “AN” position (factory default), the corresponding

port automatically determines the duplex and pause modes of the connected device. If the

3) CONFIGURE MODULE VIA COMMAND LINE INTERFACE
To access the Menu-Driven Interface, connect the GM4 RS-232 Serial Console Port to the

COM port of a computer equipped with terminal emulation software such as HyperTerminal.

The Console Port (DCE) is a mini DIN-6 female connector which can be changed to a

DB-9 connector with the included adapter. The GM4 Console Port is a standard RS-232

asynchronous serial interface.
Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:”

window. Set the serial port to the following:
Bits Per Second

57,600

Stop Bits

1

Data Bits

8

Parity

NONE

Hardware Flow Control

NONE

The Menu-Driven Interface enables detailed configuration of the module.
4) VERIFY OPERATION
Once the module has been installed and configured per steps 1 - 3, verify the module is

operational by viewing the LED indicators.

LED Function

“Legend”

Color

OFF State

ON/Blinking State

Power

“PWR”

Green

No power

ON: Module has power

P1 Link Activity

“100”

Green

Port not linked at 100M

ON: Port linked at 100M

Blinking: Data activity

P1 Link Activity

“1000”

Green

Port not linked at 1000M

ON: Port linked at 1000M

Blinking: Data activity

P1 Link Activity

“100” and “1000”

Green

Port not linked at 10M

ON: Port linked at 10M

Blinking: Data activity

P2 Link Activity

“100”

Green

Port not linked at 100M

ON: Port linked at 100M

Blinking: Data activity

P2 Link Activity

“1000”

Green

Port not linked at 1000M

ON: Port linked at 1000M

Blinking: Data activity

P2 Link Activity

“100” and “1000”

Green

Port not linked at 10M

ON: Port linked at 10M

Blinking: Data activity

Test/Alarm

“Tst/Alm”

Green

Reserved

Reserved

Management Mode

“Msr/Slv”

Green

N/A

ON: Master (normal)

5 Hz Blinking: Secure Slave

P3 Link Activity

“100”

Green

Port not linked at 100M

ON: Port linked at 100M

Blinking: Data activity

P3 Link Activity

“1000”

Green

Port not linked at 1000M

ON: Port linked at 1000M

Blinking: Data activity

P3 Link Activity

“100” and “1000”

Green

Port not linked at 10M

ON: Port linked at 10M

Blinking: Data activity

Figure 5: LED Indicators