the fault at the fiber port is propagated forward causing

the switch port to drop its link due to the propagated

fault [Fig 1(c)].
The Remote Fault Detection (RFD) mode transmits a

link signal only when a link signal is detected. When a

loss of link is detected, this mode will perform both a loop

back and propagate forward. For example, the fiber fault

is looped back in the opposite direction causing the port

on the other media converter to lose fiber link. It also

propagates the fault forward toward the UTP port causing

the switch port to lose link [Fig 1(d)].
Note: Connecting two converters set to RFD is an

illegal setting and will cause a “deadly embrace”

lockup.
Symmetrical Fault Detection is only supported on

modules with the revision of xx/08.
In Symmetrical Fault Detection (SFD), the UTP port

transmits a Link signal only when receiving a Link at

the fiber port. The fiber port transmits a Link signal only

when receiving a Link signal at both the fiber port and

the UTP port. As a result, fiber faults (no Link received

at the fiber) are looped back and can be reported to the

network core. In addition, connecting two back-to-back

converters which are both set to SFD facilitates dual-

loop-back, where fiber faults are reported to both ends of

the network link. A blinking fiber link LED on a converter

indicates a fault of the transmit fiber or UTP cables of

that converter [Fig. 1(e)].
Note: Converters in SFD mode must be deployed

in pairs.

FRONT PANEL DIP-SWITCH SETTINGS:

Link Prop = Link Propagate

R/Flt Det = Remote Fault Detect
Man = UTP Manual Negotiate

HDX = UTP Half-Duplex

Link Segment = Link Seg

Normal = Norm

UTP Auto Negotiate = AN

UTP Full-Duplex = FDX

SW1

SW4

Fig. 2 Front Panel DIP-Switches

SW1

SW2

Link Mode

LS

Normal Link Segment (LS)

LP

Normal Link Propagate (LP)

LS

RFD

Remote Fault Detection + LP

(RFD+LP)

LP

RFD

Illegal Setting

Fig. 3 Link Mode Selection Table

SW1

SW2

Link Mode

LS

Normal Link Segment (LS)

LP

Normal Link Propagate (LP)

LS

RFD

Remote Fault Detection + LP

(RFD+LP)

LP

RFD

Symmetrical Fault Detection (SFD)

Fig 4 Link Mode Selection Table for Revision xx/08
UTP Auto/Manual Negotiate “AN/Man” DIP-Switch:

When this DIP-Switch is in the UTP Auto-Negotiate

“AN” position (factory setting), the converter auto-

negotiates and matches the duplex mode of a mating

OVERVIEW:

The

iConverter

100Fx/Tx converters support the IEEE

802.3 Ethernet standard and converts 100BASE-FX fiber

to 100BASE-TX unshielded twisted pair (UTP). Models

are available for multimode (MM) and single-mode (SM)

dual fiber and single-mode single-fiber.
The 100Fx/Tx supports UTP Half-Duplex and Full-Duplex

auto-negotiation with manual override and features a

crossover UTP switch for easy attachment to hubs,

switches and workstations.
The 100Fx/Tx can be used in an unmanaged or managed

fashion. When unmanaged, it can be installed in a chassis

without an

iConverter

Network Management Module

(NMM) or

iConverter

10/100M2. To be managed, an

NMM module or 10/100M2 module must be installed in

the same chassis.

LINK MODES:

In order to accommodate different user needs, the 100Fx/

Tx supports three different linking modes.
The Link Segment (LS) mode transmits a link signal

independently of any received link at any port. Utilizing

this configuration, a loss of a receive link signal will only

affect the port detecting the loss of signal. All the other

ports will continue to generate a link signal. For example

a loss of link on the fiber port only affects the fiber port;

the other ports remain unaffected [Fig 1(b)].
The Link Propagate (LP) mode transmits a link signal only

when a link signal is detected. Utilizing this configuration,

a loss of a receive link signal will continue to propagate

through to the next port in the network. For example,

LED Lit

LED Blinking

LED Off

LED Status depends on connected device

Switch 1

Converter A

Converter B

Switch 2

(a)

LS

Fiber

UTP

UTP

Fiber

LS

Switch 1

Converter A

Converter B

Switch 2

LS

(b)

LS

(c)

Switch 1

Converter A

Converter B

Switch 2

LP

LP

(d)

Switch 1

Converter A

Converter B

Switch 2

SFD

SFD

(e)

Switch 1

Converter A

Converter B

Switch 2

LP

RFD+LP

Fig. 1 Link Modes

100Fx/Tx SPECIFICATIONS:

Page 7

Page 8

Page 9

Page 6

Page 10

Form: 040-08360-001J 02/14

Warning

The operating description in this Instruction Manual is

for use by qualified personnel only. To avoid electrical

shock, do not perform any servicing of this unit other than

that contained in the operating instructions, unless you

are qualified and certified to do so by Omnitron Systems

Technology, Inc.

Warranty

This product is warranted to the original purchaser

against defects in material and workmanship for a period

of TWO YEARS from the date of shipment. A LIFETIME

warranty may be obtained by the original purchaser by

REGISTERING this product with Omnitron within 90 days

from the date of shipment. TO REGISTER, COMPLETE

AND MAIL OR FAX THE ENCLOSED REGISTRATION

FORM TO THE INDICATED ADDRESS. Or you may

register your product on the Internet at www.omnitron-

systems.com. During the warranty period, Omnitron will,

at its option, repair or replace a product which is proven

to be defective.
For warranty service, the product must be sent to

an Omnitron designated facility, at Buyer’s expense.

Omnitron will pay the shipping charge to return the

product to Buyer’s designated US address using

Omnitron’s standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting

from improper or inadequate use and/or maintenance

of the equipment by Buyer, Buyer-supplied equipment,

Buyer-supplied interfacing, unauthorized modifications

or tampering with equipment (including removal of

equipment cover by personnel not specifically authorized

and certified by Omnitron), or misuse, or operating

outside the environmental specification of the product

(including but not limited to voltage, ambient temperature,

radiation, unusual dust, etc.), or improper site preparation

or maintenance.
No other warranty is expressed or implied. Omnitron

specifically disclaims the implied warranties of

merchantability and fitness for any particular purpose.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and

exclusive remedies. Omnitron shall not be liable for any

direct, indirect, special, incidental, or consequential

damages, whether based on contract, tort, or any legal

theory.

auto-negotiating device connected to its UTP port.
When in the UTP Manual Negotiate “Man” position,

the converter does not auto-negotiate and operates in

the duplex mode selected by the UTP Full/Half-Duplex

“FDX/HDX” DIP-Switch.
UTP Full/Half Duplex “FDX/HDX” DIP-Switch:
When the UTP Auto/Manual Negotiate “AN/Man”

DIP-Switch is in the Manual “Man” position, the UTP

Full/Half-Duplex “FDX/HDX” DIP-Switch determines the

duplex mode for the converter.
When the UTP Full/Half-Duplex DIP-Switch is in the UTP

Full-Duplex “FDX” position (factory setting), the converter

operates in Full-Duplex mode. When in the UTP Half-

Duplex “HDX” position, it operates in Half-Duplex mode.

Set the duplex mode to match the connecting device and

check for link status.
Note: Attaching an auto-negotiating UTP port to a

non-auto-negotiating (manual / forced / hard-coded)

UTP port may result in an unpredictable port setting

with excessive collisions and poor link performance.

When operating in Manual mode both mating ports

MUST be set manually to the same speed and duplex

mode.
RJ45 Crossover “= / X” Switch (Not Shown):

When connecting the UTP to a hub or switch, set this

front-plane switch to Straight-Through “=” (factory

setting). When connecting to a workstation, set it to

Crossover “X”.

Technical Support:
For help with this product, contact our Technical Support:
Phone:

(949) 250-6510

Fax:

(949) 250-6514

Address: Omnitron Systems Technology, Inc.

38 Tesla

Irvine, CA 92618 USA

Email:

[email protected]

URL:

www.omnitron-systems.com

LED INDICATORS:

LED Color

Description

Pwr:

Yellow On - Power on

F/O Lk:

Green On - Link; Blink - Activity

AN:

Green On - UTP Auto-Negotiation

enabled

FDx:

Green On - Full-Duplex mode

UTP/Lk:

Green On - UTP Link; Blink - Activity

MOUNTING AND CABLE ATTACHMENT:

The

iConverter

modules are hot-swappable and can be

installed into any

iConverter

chassis.

1. Using the chassis module guides for alignment, insert

the module into the selected slot and secure using the

front panel fastener screw.

Note: Ensure that the module is firmly seated

against the backplane.

2. Using a Category 5 cable, attach the UTP port to a

100BASE-TX Ethernet device.

3. Using a multimode or single-mode dual-fiber cable

as required per the converter type, attach the fiber

port to a 100BASE-FX mating Ethernet device. The

transmit (Tx) must attach to the receive side of the

mating device and the receive (Rx) must attach to the

transmit side.

4. Single-fiber (SF) converters must be used in matched

pairs. The transmit (Tx) and receive (Rx) wavelengths

of one converter must match the receive (Rx) and

transmit (Tx) wavelengths of the mating converter. For

example, an 8370-1 must be connected to an 8371-1.

Page 1

iConverter

®

100Fx/Tx User Manual

iConverter 100Fx/Tx Dual Fiber Modules

Fiber Type

Distance

Connector Types

ST

SC

LC

MM

5 km

8360-0

8362-0

8366-0

SM

30 km

8361-1

8363-1

8367-1

SM

60 km

8361-2

8363-2

8367-2

SM

120 km

-

8363-3

8367-3

iConverter 100Fx/Tx Single-Fiber Modules

Fiber /

Connector

Type

Distance

Tx: 1310nm,

Rx: 1550 nm

Tx: 1550nm,

Rx: 1310nm

SM/SC

20 km

8370-1

8371-1

SM/SC

40 km

8370-2

8371-2

For wide temperature (-40 to 60°C), add a “W” to the end of the model

number. Consult factory for extended temperature (-40 to +75°C)

models. When using single-fiber (SF) media converter models, the Tx

wavelength on one end has to match the Rx wavelength on the other.

Consult factory for additonal fiber configurations.

Model Type

100 Fx/Tx

Protocols

100BASE-FX, 100BASE-TX

Copper

Connectors

RJ-45

Fiber

Connectors

SC, ST, LC,

Single-Fiber SC

Controls

UTP X-over, LS/LP, RFD,

UTP FDX/HDX, UTP A/N

LED Displays

Power, FO link, UTP link,

Auto, FDX/HDX

Dimensions

W: 0.85” x D: 4.5” x H: 2.8”

Weight

8 oz.

Compliance

UL, CE, FCC Class A,

NEBS Level 3

Power

Requirement

0.7A @ 3.3VDC (typical)

Temperature

Standard: 0 to 50°C

Wide: -40 to 60°C

Storage: -40 to 80°C

Humidity

5 to 95% (non-condensing)

Altitude

-100m to 4000m

MTBF (hrs)

730,000