Warning, F. horizontal termination, Elbow in corner installation – Quadra-Fire SAPPHIRE-D-CSB User Manual

Page 12

Advertising
background image

12

Quadra-Fire • Sapphire • 7055-116 Rev. D • 6/11

F. Horizontal Termination

45° Elbow

3 in. (76mm) Clearance from appliance
corner to combustible wall

3 in. (76mm)
Clearance from
appliance corner to
combustible wall

Wall Thimble/Heat Shield

Wall Thimble/

Heat Shield

Wall Thimble Cover

Pipe Length

Pipe Length

Termination Cap

Center Line

90° Elbow

Type A - Up and Out Installation

Type B - Straight Out Installation

Type C - 45

°

Elbow in Corner Installation

Wall Thimble
Cover

Pipe Length

Snorkel Kit

Wall Strap 14 in.
(356mm) Wide

Minimum 6 in.
(152mm) of pipe
through wall

Wall Thimble or Heat Shield

15-5/8 in.
(397mm)

21 in. (533mm)

Center Line

Figure 5.4

Female Locking Lugs

Male Locking Lugs

Step 1.
Determine the desired location of the appliance. Check
to ensure that wall studs or roof rafters are not in the way
when the venting system is attached. If this is the case, you
may want to adjust the location of the appliance.

Figure 5.5

Step 2.
Direct vent pipe is designed with a locking connection. To
connect the venting system to the appliance flue outlet, a
twist-lock adapter is built into the appliance at the factory.
Wall thickness may vary. Remember to include wall
thickness in minimum clearances when figuring venting
lengths for your installation needs.

Note: Female ends of direct vent pipe/elbows are
designed to slide straight onto the male ends of adjacent
pipes by orienting the pipe indentations so they match and
slide into the entry slots on the male ends, see

Figure 5.5.

Push the pipe sections completely together, then twist-lock
one section clockwise approximately one-quarter turn, until
the two sections are fully locked. The female locking lugs
may not be visible from the outside. They may be located by
examining the inside of the female ends.

Fire Risk.

Explosion Risk.

Combustion Fume Risk.
Use vent run supports per installation instructions.

Connect vent sections per installation instructions.

• Maintain all clearances to combustibles.

• Do NOT allow vent to sag below connection

point to appliance.

• Maintain specifi ed slope (if required).

WARNING

Improper support may allow vent to sag or separate.

Fire Risk.

Exhaust Fume Risk.

Impaired Performance of Appliance.

WARNING

• Ensure vent components are locked together correctly.

• Pipe may separate if not properly joined.