Listing and code approvals, Warning – Quadra-Fire SAPPHIRE-D-CSB User Manual

Page 4

Advertising
background image

4

Quadra-Fire • Sapphire • 7055-116 Rev. D • 6/11

1

Listing and Code Approvals

The product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burning
Heating Appliances for Manufactured Homes and Recre-
ational Vehicles” and "Gas Fired Appliances for use at High
Altitudes".

A. Appliance Certifi cation

B. Glass Specifi cations

NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the

National

Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A.
and the

CAN/CGA B149 Installation Codes in Canada.

D. High Altitude Installations

Intertek listed gas appliances are tested and approved
without requiring changes for elevations from 0 to 2000 feet
(0 to 609m) in the U.S.A. and 0 to 4500 feet (0 to 1372m)
in Canada.

When installing this appliance at an elevation above 2000
feet (609m), it may be necessary to decrease the input
rating by changing the existing burner orifi ce to a smaller
size. Input rate should be reduced by 4% for each 1000 feet
(305m) above a 2000 foot (609m) elevation in the U.S.A. If
the heating value of the gas has been reduced, these rules
do not apply. To identify the proper orifi ce size, check with
the local gas utility.

If installing this appliance at an elevation above 4500 feet
(1372m) in Canada, check with local authorities.

C. BTU Specifi cations

This appliance is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.

WARNING

Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect
the unit and to replace any part of the control system and
any gas control which has been under water.

Manufactured Home or Mobile Home installation may occur

only after the home is site located and must conform with
the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, or, when such a standard is
not applicable, the Standard for Manufactured Home
Installations, ANSI/NCSBCS A225.1, or Standard for Gas
Equipped Recreational Vehicles and Mobile Housing, CSA
Z240.4.

When installed, the appliance must be electrically grounded

in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.

Materials that are reported as passing

ASTM E 136,

Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750°C
, shall be considered non-
combustible materials.

Materials made of or surfaced with wood, compressed

paper, plant fibers, plastics, or other materials that can ignite
and burn, whether flame proofed or not, or whether plastered
or unplastered shall be considered combustible materials.

E. Non-Combustible Materials

F. Combustible Materials

MODEL:

Sapphire-D Gas Stove

LABORATORY: Intertek, Report No. 3198461

TYPE:

Direct Vent Gas Heater

STANDARD:

ANSI Z21.88b-2009

ּ

CSA 2.33b-2009

ּ

UL307b

ּ

CAN/CBA 2.17-M91

Model

(US or Canada)

Maximum

Input

BTU

Minimum

Input

BTU

Orifi ce

Size

(DMS)

*Steady

State

Effi ciency %

**P.4

%

TOP VENT:

(NG)
(LP)

30,000

21,000

.106

80.92

58.90

28,500

19,700

.063

82.44

60.09

REAR VENT:

(NG)

(LP)

26,000

18,000

.098

80.92

65.04

26,000

19,000

.059

82.44

66.49

* Thermal effi ciency maximum pipe with blower on.
** Canada minimum pipe.

Advertising