Caution mains voltage, Figure 5-7: adjustment locations – Tektronix 1705A User Manual

Page 114

Advertising
background image

Checks and Adjustments

1705A Spectrum Monitor

5- 19

2.

Adjust CRT Bias

a.

Turn the INTENSITY control fully counterclockwise.

b. ADJUST

-- R58 (CRT BIAS) so that the display is just extinguished.

c.

Set INTENSITY control for a useable display.

CAUTION

MAINS

VOLTAGE

A1 PWR SPLY BD

R11

R45

R49

R58

W1 +5V

CRT
BIAS

ASTIG

GEOM

FOCUS

W4 --15V

W3 +15V

A3 MAIN BD

FRONT

R99

R111

L4

FL1

C69

J11

FL2

C52

C64

C62

R175

R176

R232

R239

R240

W12

W11

R168

R140

R113

R89

W8

R27

R29

R55
R56

R57

W5

W2

R48

R49

R4

R36

R37
R38

R61

R35

R82

R51

R58

R75

R81

+5V

ADJ

R99

Figure 5-7: Adjustment locations