Tektronix 1705A User Manual

Page 142

Advertising
background image

Maintenance

1705A Spectrum Monitor

6- 17

Connect the oscilloscope probe to the anode of CR5 and the probe ground to
TP1. The signal should be a clipped sine wave of +75 to +200 V p-p.

High Voltage Oscillator Check

Connect the oscilloscope probe to T1 pin 3 (Q6 collector) and the probe ground
to TP1. Power up the supply. The signal should be a +60 V p-p, 22 kHz sine
wave.

Check the following voltages using the digital multimeter:

Table 6- 6: High Voltage Oscillator Test Points

Circuit Location

Voltage

T1, pin 4

Approximately +40 V.

T1, pin 13

Less than +2 V.

U2, pin 2

Approximately +4.8 V.

U2, pin 6

+4 to +11 V.

CR9, cathode

Approximately +100 V.

CRT Voltage Check

NOTE. This check requires a high voltage probe having an input resistance of 1
G

Ω or more.

Connect the high voltage probe ground to TP1.

Load the Low Volts Supply with the instrument, or with a 20

Ω, 2 watt resistor

loading the 5 V supply.

Power up the Power Supply.

Use the high voltage probe to measure the voltage at the anode of CR4. It
should be approximately --2530 V.

Measure the voltage at the anode end of CR3. It should be 50--150 V more
negative than the reading from the anode of CR4.

Advertising