5 showing constant list and switch on/off, Compensation systematic error of instrument -11 – Topcon GTS-823A User Manual

Page 110

Advertising
background image

9-11

9 CHECK AND ADJUSTMENT

9.5

Showing Constant List and Switch ON/OFF
Compensation Systematic Error of Instrument

[Example setting: Switch OFF the compensation]

Operating procedure

Operation

Display

1

Press [F5] key from the main menu.

[F5]

2

Press [F2] key .
Correction values are displayed.

[F2]

3

Press [F6](OFF) key.

[F6]

4

Press [F1](EXIT) key.
The display returns to main menu.

[F1]

Adjustment

F1 V0/Axis (Measurement)

F2 V0/Axis (Constant list)

F3 Date Time

F4 Instrument constant

Vco: -1°57'12"

Hco: -0°00'20"

HAx: -0°00'20"

EXIT ON OFF

Vco: -1°57'12"

Hco:

HAx:

EXIT ON OFF

Advertising