4-13

4 STANDARD MEASUREMENT MODE

4.3.3 Execution of Coordinate Measuring

Measure the coordinates by entering the instrument height and prism height, coordinates of unknown
point will be measured directly.

l

When setting coordinate values of occupied point, see Section 4.3.1“Setting Coordinate Values of
Occupied Point” .

l

When setting the instrument height and prism height, see Section 4.3.2“Setting of the Instrument
Height / Prism Height” .

l

The coordinates of the unknown point are calculated as shown below and displayed:

Coordinates of occupied point : (N

0

, E

0

, Z

0

)

Instrument height

: Inst.h

Prism height

: R.h

Vertical distance (Relative elevation) : z
Coordinates of the center of the prism,
originated from the center point of the instrument

: (n,e,z)

Coordinates of unknown point : (N

1

, E

1

, Z

1

)

N

1

= N

0

+ n

E

1

= E

0

+ e

Z

1

= Z

0

+ Inst.h + z - P.h

Confirm the angle measurement mode.

Operating procedure

Operation

Display

1

Set coordinates values of occupied point and
instrument/prism height. *1)

2

Set the direction angle of known point A. *2)

Set

direction

angle

3

Collimate target B.

Collimate

4

Press [F3](NEZ) key.*3)
Measuring starts.

[F3]

Origin (o, o, o)

Occupied point (No, Eo, Zo)

Center point of the instrument
(No, Eo, Zo + Inst.h)

Coordinates of the center of the prism, originated from the center point of the instrument (n,e,z)

Unknown point

(N

1

, E

1

, Z

1

)

V : 90

°10'20"

HR: 120

°30'40"

SD HD NEZ 0SET HOLD P1

N :

<

E : PSM 0.0

Z : PPM 0.0

(m) *F.R

MEAS MODE VH SD HD P1