Topcon GTS-823A User Manual

Page 84

Advertising
background image

5-26

5 PROGRAM MODES

heat simmer, or happens cut off the optical path, in such cases it takes long
time for communication or results failure. You are offered to set [Divided] item.

4) REC TYPE

Select the option to record the data for the distance measurement.

REC-A

:

Measure the distance again and record the updated distance.

REC-B

:

Record the data for the last distance measurement on the display.

(4)Setting Parameters for Radio Modem
Set the parameters for Radio Modem.

Parameters
1) Channel (Only for certain market)

Sets communication channel
The same channel must be set for GTS-820A series and Radio Modem.

Operating procedure

Operation

Display

Execute Section 5.7.1“Starting compatible
communication program of AP-L1A”
to start
[EXT.LINK] of compatible communication
program of AP-L1.

1

Press the [F2](Setting) key.

[F2]

2

Press the [F3] key to select [3 PARAMETER
(RC)].

[F3]

3

Select a channel by pressing the [F3](

) or

[F4](

) key then press the [F1](SET) key.

[F3]

or

[F4]
[F1]

4

Select Terminate by pressing the [F3](

) or

[F4](

) key then press the [F1](SET) key.

[F3]

or

[F4]
[F1]

5

Select Retry by pressing the [F3](

) or [F4](

)

key then press the [F1](SET) key

[F3]

or

[F4]
[F1]

6

Set REC TYPE in the same way.

[F3]

or

[F4]
[F1]

l

To cancel the setting, press the [F6](EXIT)key or the [ESC] key.

EXTERNAL LINK

1 Execute

2 Setting

Setting

1 CABLE/RADIO MODEM/RC

2 PARAMETER(CABLE)

3 PARAMETER(RC)

4 PARAMETER(RADIO MODEM)

CHANNEL

1

SET

EXIT

TERMINATE

ETX

SET

EXIT

RETRY

Standard

SET

EXIT

REC TYPE

REC-A

SET

EXIT

Setting

1 CABLE/RADIO MODEM/RC

2 PARAMETER(CABLE)

3 PARAMETER(RC)

4 PARAMETER(RADIO MODEM)

Advertising