8-2

8 PARAMETERS SETTING MODE

Dist. Unit

METER /FEET

Select the distance measuring unit Meter or Feet shown on
the display.

C.F. m/ft

Us.f /Intl.f

Select the meter / feet conversion factor.
US SURVEY feet

1m =3.280833333333333 ft.

INTERNATIONAL feet

1m =3.280839895013123 ft.

Min. Dist.

OFF / ON

Select OFF or ON for the minimum distance in fine mode.
OFF:1mm :ON: 0.2mm

S/A buzz.

OFF / ON

Select the Audio tone OFF or ON for the Set Audio Mode.

W-corr.

OFF/ 0.14 / 0.20

Select the coefficient correction for refraction and earth
curvature. Selections for the refraction coefficient are;
OFF (No correction), K=0.14 or K=0.20.

N/E/Z mem

OFF / MEM.ON

Select the option to store the coordinates (NEZ) for the
occupied point when power is turned off.

N/E- ord.

NEZ / ENZ

Select the display format in the coordinate measurement
mode for NEZ or ENZ.

Temp. Unit

°C / °F

Select the temperature unit for the atmospheric correction.

Pres. Unit

mmHg/inHg/hPa

Select the air pressure unit for the atmospheric correction .

R/L Lock

OFF / ON

Prohibit switching angle right or left by soft key in angle
measurement mode
OFF : Switching is possible ON : Prohibition

m/ft Lock

OFF / ON

Prohibit switching meter unit or feet unit.
OFF : Switching is possible ON : Prohibition

Date

d / m / y
m / d / y
y /m / d

Select the date format shown on the display.
(Month / Date / Year) , (Date/Month/ Year) or (Year / Month /
Date)

A. P. OFF

OFF / ON (01 to 99)

The auto power off function can be turned OFF or set ON.
OFF : not use ON :1 to 99 minutes (numeric key)

Heater

OFF / ON

The heater option for both display units can be turned OFF or
ON.

EDM wait

OFF / ON (01 to 99)

EDM cut off time after distance measurement is completed
can be changed.
OFF : EDM is cut off immediately after measuring
ON : EDM is cut off after 1 to 99 minutes.

Ini. mode

Menu / Std / E.Link

Select the initial mode when powering on.
Menu : Menu Std : Standard measurement
E.Link : External link

Self chk

OFF / ON

Select the self check function ON or OFF when powering on.

Advertising
This manual is related to the following products: