background image

8-4

8 PARAMETERS SETTING MODE

Retry

Std. / Div.

Selecting the method of the data re-transmitting.
Std (Standard)

: This is offered in normal condition.

Div.(Divided)

: Using in bad condition such in long

distance, bad condition of sight, strong
heat simmer.

Delimit

ETX / CRLF

Select the option OFF or ON for carriage return and line feed
when collecting measurement data with a computer.

REC-A/B

A / B

Select the option to record the data.
REC-A :The measurement is started and new data is output.
REC-B :The data being displayed is output.

NEZ-REC

Std / Exp

Record coordinates in standard or Data with slope distance
and horizontal angle data.

Trk State

OFF / ON

Selecting additional information of utility to measuring data
such as tracking status or not.
If such utility is selected, electric circular level graphic will not
be displayed whenever tilted over.
OFF :No additional information
ON

:Additional information

B. Rate

4800

Fixed

Data. L

8

Fixed

Parity

none

Fixed

Stop Bit

1

Fixed

Advertising