5-22

5 PROGRAM MODES

5

Collimate the left side of the column (P2) and
press the [F6](SET) key.

After the measurement, angle measuring
display of the right side (P3) will be shown.

Collimate

P2

[F6]

6

Collimate the right side of the column (P3)
and press the [F6](SET) key.

After the measurement, the distance between
the instrument and center of the column (P0)
will be calculated and displayed.

Collimate

P3

[F6]

7

To show the slope distance of point P0, press
the [F2](SD) key.

[F2]

8

To show the coordinates, press the [F3](NEZ)
key. *1)

[F3]

*1) To repeat the offset measurement, press the [F1](NEXT) key. The display will return to step 4.

COLUMN OFFSET

Right

HR : 95

°30'40"

SET

COLUMN OFFSET

HR: 90°30'40"

HD: 10.321 m

VD: 0.886 m

NEXT SD NEZ REC

COLUMN OFFSET

V : 85°30'30"

HR: 90°30'40"

SD: 10.999 m

NEXT HD NEZ REC

COLUMN OFFSET

N : 17.321 m

E : 10.962 m

Z : 0.886 m

NEXT SD HD REC