Retry Selection

Program

⇒

Protection

⇒

Retry/Restart

After a trip has occurred, this parameter sets the number of times that an
automatic system restart is attempted for a qualified trip.

The trip conditions listed below will not initiate the automatic Retry/Restart
function:

•

Input Phase Loss (Input Phase Failure)

•

Output Phase Loss (Output Phase Failure)

•

Output Current Protection Fault

•

Output Current Detector error

•

Load side overcurrent at start

•

Earth Fault (Ground Fault)

•

Overcurrent During Acceleration

•

Arm Overcurrent at start-up

•

DBR Resistor Overcurrent

•

Low Current

•

Voltage Drop In Main Circuit

•

EEPROM Data Fault (EEPROM Fault)

•

Flash Memory/Gate Array/RAM-ROM Fault

•

CPU Fault

•

Emergency Off (EMG)

•

Communication Error

•

Option Fault

•

Sink/Source Setting Error

•

Overspeed Error

•

Overtorque

•

Key Error

•

External Thermal Error

•

Externally-controlled Interrupt

See the section titled

System Setup Requirements on pg. 8

for more information

on this setting.

Direct Access Number — F303

Parameter Type — Numerical

Factory Default — 00

Changeable During Run — Yes

Minimum — 00

Maximum — 10