Control lock and control keys, Control keys control lock, Control keys – Toshiba TEC MA-1350-1 User Manual

Page 11: Control lock

Advertising
background image

- 4 -

EO1-11126

MA-1350-1 SERIES

5. Control Lock and Control Keys

Control Keys

There are four types of Control keys: the REG key, the MGR key, the MA key, and the S key.

REG Key:

The REG key is used by the cashier or clerk who operates ordinary transaction
entries. This key can access the positions of OFF and REG of the Control Lock.

MGR key:

The MGR key is used by the store manager. This key can access the positions
of OFF, REG, X, and MGR.

MA Key:

The MA key is used by the owner who will daily supervise the collection of
money and printout of transactions recorded by the register. This key is also
used when programming the register. This key can access the positions of SET,
OFF, REG, X, MGR, - and Z.

S Key:

The S key is used by the service person from your TOSHIBA TEC
representative to access any position. To prevent programmed data and sales
data from being changed or cleared by mistake, do not use this key without
instructions from your TOSHIBA TEC representative.

Control Lock

The Control Lock has seven effective positions for different modes of operation, which are accessed by the
appropriate Control Keys.

(position)

(function)

SET ............... The register allows programming and training operations.

OFF ............... Nothing appears on the display in this position. However,

the power is being supplied to the register.

REG .............. Transaction entries are carried out in this mode. Displays

the current time while no entries are under way.

X ................. The sale totals in memory can be read (X reports) and

the programmed data can be verified in this position.

MGR .............. This position allows to enter operations requiring Man-

ager Intervention as well as all ordinary transaction en-
tries to be carried out in the “REG” mode.

- .................. This is the “Negative Mode” position, which makes en-

tered data processed reversely to the REG or MGR
mode. It is used to cancel or adjust sales data already
finalized.

Z ................. All the resettable totals and their respective counters in

memory will be read and reset in this position (Z reports)

The keys may be inserted or pulled out at the “OFF” or “REG” position.

REG

MGR

MA

S

MA

MGR

REG

OFF

REG

X

SET

MGR

-

➤ ➤

Z