Toshiba – Toshiba S2E21 User Manual

Page 63

Advertising
background image

TOSHIBA

Where

temperature rise of the rotor at time t

S: temperature rise of the

at time t (C)

TR:

heating time constant of the motor (minute) (set value)

When the load current is higher than 2.5 times the rated current

(2.5 x IN

From the heating characteristic during locking that

by the

motor starting current (1st) and the allowable locking time. the temper-
ature rise of the rotor is simulated.

When at time the rotor is locked, then

l(t),

1

=

) .

.

TSC

t

. . . . . . . . . . . . . ...(5)

Where R(t): temperature rise of the rotor at time t

temperature rise of the rotor before the rotor is

locked (C)

load current at time t (A)

starting current (A) (setting value)

TSC:

allowable locking time in the cold state

(setting value)

allowable temperature rise of the rotor CC)

(fixed at

When

=

the trip operation is carried out.,

The operation characteristic (operating time) in the locked state varies

depending on the heated condition of the motor and the conducting current.