10.3.3 Signal Treatment

Driver types and requirements for the signal pull- up and down are as follows. Resistor requirement is minimum for the host.
- IO16 is pulled up in the drive with certain value so that the Vol is obtained to run with a host that has large value of pull up

resistor. - CS0 and - CS1 are also pulled up for better noise immunity.

Table 10.3-2 Signal treatment

SIGNAL

Driven by

TYPE

By host

By drive

- RESET

host

TP

10k

PU

DD 0:15

bi-direction

TS

DMARQ drive TS 5.6

k

PD

-

DIOR host TS

-DMARDY

HSTROBE

- DIOW

host

TS

STOP

IORDY

drive

TS

1.0 k

PU

-DDMARDY

DSTROBE

CSEL

host

GND

10 k

PU

- DMACK

host

TP

INTRQ drive TS

10

k

PD

- IOCS16

drive

OD

1.0 k

PU

1.2 k

PU

DA 0:2

host

TP

- PDIAG

-CBLID drive

TS

10

k

PU

- CS0 - CS1

host

TP

- DASP

drive

OD

10 k

PU

TP = Totem Pole, TS = Tri-State, PD = Pull Down, PU = Pull-Up, OD = Open Drain