Toshiba MK6017MAP User Manual

Page 74

Advertising
background image

360014937

Copyright ©2000 Toshiba corporation. All rights reserved.

- 574 -

Table 10.8-1 Identify Information

WORD

DESCRIPTION

Hex.

0 General

configuration

15 0=ATA device
14-8 Reserved
7 1=Removable cartridge device
6 1=Fixed device
5-3 Reserved
2 Response incomplete
1-0 Reserved

0040

1

Number of default logical cylinders

[1*]

2 Specific

configuration

C837

3

Number of default logical heads

[2*]

4 Reserved

0000

5 Reserved

0000

6

Number of default logical sectors h logical track

[3*]

7-9 Reserved

10-19

Serial Number (20 ASCII characters)

20 Reserved

0000

21 Reserved

0000

22

Number of vendor specific ECC bytes transferred on READ/WRITE LONG
commands

002E

23-26

Firmware Revision (8 ASCII characters)

27-46

Controller model # (40 ASCII characters)

47

15-8 80h
7-0

00

H

= READ/WRITE MULTIPLE command not implemented

01

H

- FF

H

= Maximum number of sectors that can be transferred per

interrupt on READ/WRITE MULTIPLE commands

8010

48

Reserved

0000

49 Capabilities

15-14 Reserved
13 1=Standby timer values as specified in ATA/ATAPI-5 specification are
supported
0=Standby timer values are vendor specific
12 Reserved
11 1=IOCHRDY supported
10 1=IOCHRDY can be disabled
9 1
8 1
7-0 Reserved

0F00

50 Capabilities

15 0 (Fixed)
14 1 (Fixed)
13-1 Reserved
0 1= a device specific Standby timer value minimum.

4001

51

15-8 PIO data transfer cycle timing mode
7-0 Reserved

0200

52

Reserved

0000

53

15-3 Reserved
2 1=the fields reported word 88 are valid
0=the fields reported word 88 are not valid
1 1=the fields reported words 64-70 are valid
0=the fields reported words 64-70 are not valid
0 1=the fields reported words 54-58 are valid

0=the fields reported words 54-58 are not valid

0007

54

Number of current cylinders

XXXX

55

Number of current heads

XXXX

56

Number of current sectors per track

XXXX

Advertising