26 set features (efh) – Toshiba MK6017MAP User Manual

Page 87

Advertising
background image

360014937

Copyright © 2000 Toshiba corporation. All rights reserved.

-

587 -

10.8.26 Set Features (EFh)

COMMAND CODE

1 1 1 0 1 1 1 1

REGISTER

REGISTER SETTING

NORMAL COMPLETION

DR

DRIVE No.

no change

CY

no

change

HD

no

change

SN

no

change

SC

Mode Selection for Data Transfer(*2)

no change

FT Features(*1)

no

change

(*1) Features: FT register defines following selections.

02H

Enable write cache feature

03H

Select data transfer mode

05H

Enable advanced power management

44H

ECC length is 46 bytes during Read/Write Long command

55H

Disable read look-ahead feature

66H

Disable reverting to power on defaults by soft reset

82H

Disable write cache feature

85H

Disable advanced power management

AAH

Enable read look-ahead feature

BBH

ECC length is 4 bytes during Read/Write Long command

CCH

Enable reverting to power on defaults by soft reset

others

Invalid (reporting with Aborted Command Error)

(*2)Mode selection for data transfer is specified in sector count register. Upper 5 bits show transfer mode
and lower 3 bits show mode figure.

PIO default transfer mode

00000 000

PIO default transfer mode, disable IORDY

00000 001

PIO flow control transfer mode nnn

00001 nnn

Single word DMA mode nnn

00010 nnn

Multiword DMA mode nnn

00100 nnn

Ultra DMA mode nnn

01000 nnn

Reserved 10000

nnn

PIO default mode is mode 4 flow control. DMA default mode is Multiword word DMA mode 2.

The level of Advanced Power Management function is set in Sector count register.

C0h-FEh

Mode0 (Power save up to Performance Idle)

80h-BFh

Mode1 (Power save up to Low Power Idle)

01h-7Fh

Mode2 (Power save up to Standby)

00h,FFh

Aborted


Transition time of power save is changed dynamically in Mode1 and Mode2 due to Adaptive power control
function. The function level is set to Mode1 when Advanced Power Management function is disabled.

If FT register has any other value, the drive rejects the command with Abort Command error.

Default settings after power on or hard reset are:

Data transfer mode of Multiword DMA mode 2, PIO mode 4 flow control,

4 bytes ECC, look-ahead read enabled, write cache enabled, advanced power management enabled,

READ/WRITE Multiple command enabled (16 sectors)

and reverting to power on defaults by soft reset disabled.