Toshiba MK6017MAP User Manual

Page 95

Advertising
background image

360014937

Copyright © 2000 Toshiba corporation. All rights reserved.

-

595 -

BYTE 362: Off-line data collection status

Value Definition

00h or 80h

Off-line data collection activity was never started.

01h Reserved

02h or 82h

Off-line data collection activity was completed without error.

03h Reserved

04h or 84h

Off-line data collection activity was suspended by an interrupting command from host.

05h or 85h

Off-line data collection activity was aborted by an interrupting command from host.

06h or 86h

Off-line data collection activity was aborted by the device with a fatal error.

07h-FFh Reserved


BYTE 363: Self-test execution status

The self-test execution status byte reports the execution status of the self-test routine.

Bits 0-3 (Percent Self-Test Remaining) The value in these bits indicates an approximation of the
percent of the self-test routine remaining until completion in ten percent increments. Valid values are
0 through 9. A value of 0 indicates the self-test routine is complete. A value of 9 indicates 90% of
total test time remaining.

Bits 4-7 (Self-test Execution Status) The value in these bits indicates the current Self-test Execution
Status .

Self-test execution status values

Value Description

0

The previous self-test routine completed without error or no self-test has ever been run

1

The self-test routine was aborted by the host

2

The self-test routine was interrupted by the host with a hard or soft reset

3

A fatal error or unknown test error occurred while the device was executing its self-test
routineand the device was unable to complete the self-test routine.

4

The previous self-test completed having a test element that failed and the test element
that failed is not known.

5

The previous self-test completed having the electrical element of the test failed.

6

The previous self-test completed having the servo (and/or seek) test element of the test
failed.

7

The previous self-test completed having the read element of the test failed.

8-14 Reserved.

15

Self-test routine in progress.


BYTE 364-365: Total time
The time for off-line data collection operation ( sec.)
BYTE 366: Reserve
BYTE 367: Off-line data collection capability

bit 0 (Execute off-line immediate implemented bit)
bit0 = 1 SMART EXECUTE OFF-LINE IMMEDIATE command supported.

bit0 = 0

SMART EXECUTE OFF-LINE IMMEDIATE command NOT supported

This bit is set to 1

bit 1 Reserved

bit 2 (abort/restart off-line by host)
bit2 = 1 If another command is issued, off-line data collection operation is aborted.
bit2 = 0 If another command is issued, off-line data collection operation is interrupted and then

the operation will be continued.

bit 3 (off-line read scanning implemented bit)
If this bit is cleared to zero, the device does not support off-line read scanning. If this bit is set to
one, the device supports off-line read scanning. This bit is set to 1.