Installation and Replacement

3-9

Configuring the Serial Interface

Setting the Interface Type

Introduction

This section provides instructions for setting the Interface Type parameter.

Interface Type
Parameter

Use this procedure to set the Interface Type parameter:

Step

Action

Result/Description

1

From the Control Terminal
Port Main menu, select
Configure -> Port.

The Port record appears.

2

In the Port Number parameter,
type 3, then press ENTER.

Port 3 is selected.

3

In the Port Type parameter,
type FRI, then press ENTER

This defines Port 3 type as FRI.

4

In the Interfaced Type, type a
?, and then press ENTER.

The Range and Default appear:

Range = V.24, V.35, V.36, X.21, NONE

Default = V.24

Specify the Electrical Interface Type:

V.24 - V.24 Electrical Interface Type

V.35 - V.35 Electrical Interface Type

V.36 - V.36 Electrical Interface Type

X.21 - V.11 Electrical Interface
Type

NONE - Electrically disabled

5

Select an Interface Type from
the menu and press ENTER.

The Interface Type is set.