45

PRE

L

IMINAR

Y

6.1
RS-232 Connection and
Port Configuration

To interface the PlasmaView with a home theater automation/control system or a PC running
terminal emulation software, connect it to your control system or PC as shown in Figure 3-4.

Configure the RS-232 controller or PC serial port as follows: odd parity, 8 data bits, 1 stop bit
and no flow control. Set the baud rate 9600, to match that of the PlasmaView RS-232 port.

6.2
Serial Command/Response
Messages

Serial command messages to – and response messages from – the PlasmaView are in
hexadecimal format. A command/response message consists of the following:

1.

The first command or response byte. In responses from the PlasmaView, the second
character (lower-order four bits) of this byte is F to indicate a valid command (as in the
example below); when the PlasmaView receives an invalid command, the second
character is B.

2.

Two bytes that identify the sender and receiver respectively of the message. 60 is the
PlasmaView; 80 is the personal computer or control system.

3.

The second command byte.

4.

The amount of command data, in bytes (0 for commands that do not take arguments,
such as Power On/Power Off; otherwise, 1 to 7 bytes).

5.

The command data.

6.

A checksum, calculated by adding all of the bytes in the message. The lower-order (least
significant) eight bits – that is, the last two digits – of the result are sent as the checksum.

Example

This is the command for selecting the DVD/HD1 input and the response from the
PlasmaView:

6

Serial Communications

Command

(Byte 1)

Unit ID

(Sender)

Unit ID

(Receiver)

Command

(Byte 2)

Command

Data

Length

(Bytes)

Data

Checksum

DF

80

60

47

01

05

0C

(sum = 2

0C

hex)

Response

(Byte 1)

Unit ID

(Sender)

Unit ID

(Receiver)

Response

(Byte 2)

Response

Data

Length

(Bytes)

Data

Checksum

3F

60

80

47

00

-

66

(sum = 1

66

hex)

-