3 anchor weight method, Anchor weight method – Varec 4532 User Manual

Page 27

Advertising
background image

Varec, Inc.

17

4532

Mounting

5.2.3

Anchor weight method

The flexible tube is stabilized by an anchor weight:

Figure 5-6: Anchor weight application

Note!

Make sure to put the anchor weight on the tank bottom. When installing with the sus-
pended anchor weight, please use the anchor weight at a maximum of 16 kg. More
weight may cause internal breaking in the flexible tube.

Caution!

The flexible tube must be lowered carefully without bending too much and scratching
at the inner edge of the nozzle hole.

1. Insert a gasket and lower the flexible tube from the nozzle on the tank top.
2. Rotate the 4532 ATC so that you can set up the cabling in the most convenient way.
3. Tighten the tensioning wire between the lower end of the flexible tube and the

anchor weight.

4. Wrap the tensioning wire twice around a hole on the bottom hook, tighten it and

wrap a provided wire around it (see Figure 5-7 on page 16).

5. Fix the mounting flange of the 4532 ATC to the nozzle on the tank top using bolts.

Electrical compartment

Cable entry as specified

Flange

Flexible tube

approx.500 mm

From tank bottom to
element position #1

Tank height

Nozzle height

Clearance below

bottom hook

Ø26 mm(1.02")

400 mm (15.57")

(20")

Tank bottom

Ø120 mm(4.72")

222 mm(8.74")

1000mm(39.37")

41mm(1.61")

Advertising