Varec 4532 User Manual

Page 49

Advertising
background image

Varec, Inc.

39

4532

Operation and Description of Instrument Function

VH73: "Temperature X" = raw element temperature x span (VH72) + zero offset
(VH71)

VH73 Temperature X

Item type: read only

Specified element temperature selected at VH70. The displayed value is also indicated

at individual element temperature at VH10 ~ VH25. The value is calculated based on

formula indicated on above VH72.

VH74 Position X

Item type: read and write

Range: 0mm ~ 99999mm

The position of the element specified at VH70. The position of each element is entered

when "Not Even" element spacing is selected at VH85.

VH75 Resistance X

Item type: read only

The display of the specified element resistance selected at VH70.

VH76 Resistance Adj.

Item type: read and write

Default: 0

Range: -1000.0 ~ 1000.0

Adjustment of specified element resistance at VH70. Minor resistance adjustment can

be applied on the reading value.

Note!

e.g. If selected element #5 indicates 100.3 Ohm, and reference precision resistor
indicates 100.0 Ohm at the same environmental condition, then set "-0.3" in this
matrix. #5 element now has constant artificial -0.3

°C offset resistance based on raw

measurement.

VH77 Element Type

Item type: select

Selection: Pt100 (must be selected in 4532 ATC)

Note!

The 4532 ATC always consists of "Pt100" elements with "Spot" element layout. Do
not attempt to change these parameters.

VH78 Average Number

Item type: read and write

Default: 1

Range: 1 ~ 10

Number of samples for calculating the average temperature. Increasing this parameter

will prevent erratic changes in the calculated value.

Caution!

Additional sampling # will cause slower reaction time on value switch over. Maxi-
mum 1 sampling sequence will take approximately 2 sec. {total 11 elements (6 temp
elements and 5 times for 3 reference resistors)}

Advertising