2 element temperature 1: vh10 ~ vh15, 3 element temperature 2: vh20 ~ vh29, Element temperature 1: vh10 ~ vh15 – Varec 4532 User Manual

Page 42: Element temperature 2: vh20 ~ vh29

Advertising
background image

Operation and Description of Instrument Function

Average Temperature/Water Bottom Sensor and Converter

32

Installation and Operations Manual

VH07 Temperature 0

Item type: read only

Display of converted 100 Ohm reference resistor deviation value compared to actual

inserted element value in temperature probe. The reading value of reference resistor

and its deviation are continuously monitored during operation to prevent an incorrect

calculation.

VH09 Temperature 17

Item type: read only

Display of the converted 200 Ohm reference resistor deviation value compares to the

actual inserted element value in the temperature probe. The reading value of the

reference resistor and its deviation are continuously monitored during operation to

prevent an incorrect calculation. Indicated tolerance should be within ±0.15°C (±0.27°F)

depending on element characteristics.

8.1.2

Element Temperature 1: VH10 ~ VH15

(VH16~19 used only in 4539 ATC539)

VH10 ~ 19 Temperature 1 ~ 10

Item type: read only

Range: -200°C ~ 240°C

Display of individual measured element temperature.

8.1.3

Element Temperature 2: VH20 ~ VH29

( not available in 4532 ATC)

VH26 Selec. Ave Method

Item type: select

Selection: Standard, Advanced

Selection of average calculation method.

Standard

A Conventional calculation method. Regardless of tank shape, average temperature

calculation will be performed based on the following example (example: liquid

temperature).

Advertising